A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adaptive automated sinogram normalization for ring artifacts suppression in CT. | LitMetric

Ring artifacts pose a major barrier to obtaining precise reconstruction in computed tomography (CT). The presence of ring artifacts complicates the use of automatic means of processing CT reconstruction results, such as segmentation, correction of geometric shapes, alignment of reconstructed volumes. Although there are numerous efficient methods for suppressing ring artifacts, many of them appear to be manual. Along with this, a large proportion of the automatic methods cope unsatisfactorily with the target task while requiring computational capacity. The current work introduces a projection data preprocessing method for suppressing ring artifacts that constitutes a compromise among the outlined aspects - automaticity, high efficiency and computational speed. Derived as the automation of the classical sinogram normalization method, the proposed method specific advantages consist in adaptability in relation to the filtered sinograms and the edge-preservation property proven within the experiments on both synthetic and real CT data. Concerning the challenging open-access data, the method has performed superior quality comparable to that of the advanced methods: it has demonstrated 70.4% ring artifacts suppression percentage (RASP) quality metric. In application to our real laboratory CT data, the proposed method allowed us to gain significant refinement of the reconstruction quality which has not been surpassed by a range of compared manual ring artifacts suppression methods.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.522941DOI Listing

Publication Analysis

Top Keywords

ring artifacts
28
artifacts suppression
12
sinogram normalization
8
suppressing ring
8
proposed method
8
ring
7
artifacts
7
method
5
adaptive automated
4
automated sinogram
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!