Background: Clear amniotic fluid aspiration syndrome (CAF-AS) is a very rare event occurring in 0.25% of our term clear amniotic fluids deliveries. The study's aims were: 1. to characterize the risk factors and outcomes associated with Clear Amniotic Fluid Aspiration Syndrome and 2. to compare the outcomes of Clear Amniotic Fluid Aspiration to Meconium Aspiration.

Methods: This was an observational study over a 22-year period in a single level-3 medical center. Compared were parturient/labor characteristics and neonatal outcomes in cases with suspected Clear Amniotic Fluid Aspiration to cases suspected for Meconium Aspiration.

Results: Out of 79,620 term deliveries there were 66,705 (83.8%) clear amniotic fluids and 12,915 (16.2%) meconium stained amniotic fluid (MSAF). Of neonates born with clear amniotic fluid, 166 (0.25%) were diagnosed with Clear Amniotic Fluid Aspiration Syndrome (CAF-AS), while 202 (15.7%) of those born with MSAF, were diagnosed with aspiration syndrome (MSAF-AS). Both conditions had comparable rates of mild manifestation (67.5% vs 69.2%, p = 0.63). Persistent pulmonary hypertension (PPH) occurred 5 times less in CAF-AS than MSAF-AS (4% vs 20%, OR 0.17, P< 0.0001) Both conditions presented similar rates of surfactant without PPH (11.1% vs 13.4%, p = 0.87). There was 1 postnatal death in CAF-AS vs 10 in MSAF.

Conclusion: CAF-AS were quantitatively quite similar in terms of need of actual active intervention of the neonatologists in the delivery room (166 vs 202, i.e. in terms of numbers of cases and not prevalence) to MSAF-AS.We identified in these cases two major specific causes: hyperkinetic explosive deliveries in multiparas and long-lasting episodes of maternal hypotension due to epidural/spinal anaesthesia during labor. Out of 140 million births per year in the world, it should be of concern that 3 million cases are neglected nowadays. Future studies should evaluate if this CAF-AS should benefit from a more active intervention such as immediate endotracheal suction at birth, this clear fluid being very easy to suction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11164380PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0301595PLOS

Publication Analysis

Top Keywords

clear amniotic
36
amniotic fluid
32
fluid aspiration
24
aspiration syndrome
20
clear
10
fluid
9
amniotic
9
syndrome caf-as
8
amniotic fluids
8
cases suspected
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!