AI Article Synopsis

  • Glomeruli are key kidney filtration units dependent on microcirculation, but traditional imaging struggles to accurately measure their blood flow.
  • The introduction of sensing Ultrasound Localization Microscopy (sULM) allows for better visualization of kidney structures in 2D, though it has limitations in capturing comprehensive depth information.
  • By extending sULM to 3D imaging, this study enhances the ability to analyze glomerular function and assess kidney health, potentially improving diagnostic methods and patient care in clinical settings.

Article Abstract

Glomeruli are the filtration units of the kidney and their function relies heavily on their microcirculation. Despite its obvious diagnostic importance, an accurate estimation of blood flow in the capillary bundle within glomeruli defies the resolution of conventional imaging modalities. Ultrasound Localization Microscopy (ULM) has demonstrated its ability to image in-vivo deep organs in the body. Recently, the concept of sensing ULM or sULM was introduced to classify individual microbubble behavior based on the expected physiological conditions at the micrometric scale. In the kidney of both rats and humans, it revealed glomerular structures in 2D but was severely limited by planar projection. In this work, we aim to extend sULM in 3D to image the whole organ and in order to perform an accurate characterization of the entire kidney structure. The extension of sULM into the 3D domain allows better localization and more robust tracking. The 3D metrics of velocity and pathway angular shift made glomerular mask possible. This approach facilitated the quantification of glomerular physiological parameter such as an interior traveled distance of approximately 7.5 ±0.6 microns within the glomerulus. This study introduces a technique that characterize the kidney physiology which can serve as a method to facilite pathology assessment. Furthermore, its potential for clinical relevance could serve as a bridge between research and practical application, leading to innovative diagnostics and improved patient care.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2024.3411669DOI Listing

Publication Analysis

Top Keywords

ultrasound localization
8
localization microscopy
8
kidney structure
8
kidney
5
organ volumetric
4
volumetric sensing
4
sensing ultrasound
4
microscopy characterization
4
characterization kidney
4
structure glomeruli
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!