A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

All-optical instantaneous RF signal frequency measurement system based on a linear ACF with a steep slope. | LitMetric

A new microwave photonic structure for measuring the frequency of an RF signal, to the best of our knowledge, is presented. The frequency of an unknown RF signal can be determined by simply measuring the system output optical powers. The proposed frequency measurement system can be designed so that the ratio of the two system output optical powers as a function of the RF signal frequency or the amplitude comparison function (ACF) has a steep linear slope over a wide frequency range. This enables the RF signal frequency to be measured in high resolution and high accuracy. The proposed frequency measurement system has a simple and compact structure, and is free of high-speed photodetectors as well as RF components and instruments. It also has a fast response time compared to many reported photonics-based frequency measurement systems. A proof-of-concept experiment is carried out. Experimental results show a linear ACF with a slope of more than 4.4 dB/GHz over a frequency measurement range of 5-26 GHz and a frequency measurement accuracy of better than ±0.1 .

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.519808DOI Listing

Publication Analysis

Top Keywords

frequency measurement
24
signal frequency
12
measurement system
12
frequency
11
linear acf
8
acf steep
8
system output
8
output optical
8
optical powers
8
proposed frequency
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!