A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simple and fast one-step FRET assay of therapeutic mAb bevacizumab using anti-idiotype DNA aptamer for process analytical technology. | LitMetric

We developed an aptamer-based fluorescence resonance energy transfer (FRET) assay capable of recognizing therapeutic monoclonal antibody bevacizumab and rapidly quantifying its concentration with just one mixing step. In this assay, two fluorescent dyes (fluorescein and tetramethylrhodamine) labeled aptamers bind to two Fab regions on bevacizumab, and FRET fluorescence is observed when both dyes come into close proximity. We optimized this assay in three different formats, catering to a wide range of analytical needs. When applied to hybridoma culture samples in practical settings, this assay exhibited a signal response that was concentration-dependent, falling within the range of 50-2000 μg/mL. The coefficients of determination (r) ranged from 0.998 to 0.999, and bias and precision results were within ±24.0 % and 20.3 %, respectively. Additionally, during thermal and UV stress testing, this assay demonstrated the ability to detect denatured samples in a manner comparable to conventional Size Exclusion Chromatography. Notably, it offers the added advantage of detecting decreases in binding activity without changes in molecular weight. In contrast to many existing process analytical technology tools, this assay not only identifies bevacizumab but also directly measures the quality attributes related to mAb efficacy, such as the binding activity. As a result, this assay holds great potential as a valuable platform for providing highly reliable quality attribute information in real-time. We consider this will make a significant contribution to the worldwide distribution of high-quality therapeutic mAbs in various aspects of antibody manufacturing, including production monitoring, quality control, commercial lot release, and stability testing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.126349DOI Listing

Publication Analysis

Top Keywords

assay
8
fret assay
8
process analytical
8
analytical technology
8
binding activity
8
simple fast
4
fast one-step
4
one-step fret
4
assay therapeutic
4
therapeutic mab
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!