In this study, the spectrophotometric method integrated with continuous wavelet transform (CWT) and coupled discrete wavelet transform (DWT) with fuzzy inference system (FIS) was developed for the simultaneous determination of ethinyl estradiol (EE) and drospirenone (DP) in combined oral contraceptives (COCs). The CWT approach was performed in the linearity range of 0.6-6 µg/mL for EE and 0.9 to 18 µg/mL for DP. Biorthogonal with an order of 1.3 (bior1.3) at a wavelength of 216 nm and Daubechies with an order of 2 (db2) at a wavelength of 278 nm were selected as the best wavelet families for obtaining the best zero crossing point for EE and DP, respectively. The limit of detection (LOD) of 0.7677 and 0.3222 µg/mL and the limit of quantification (LOQ) of 2.326 and 0.9765 µg/mL were obtained for EE and DP, respectively. The mean recovery of 103.24% and 99.77%, as well as root mean square error (RMSE) of 0.1896 and 0.1969, were found for EE and DP, respectively. In the DWT, the absorption of the mixtures was decomposed using different wavelets named db4, db2, Symlet2 (sym2), and bior1.3. Each of the wavelet outputs was dimension reduced by the principal component analysis (PCA) method and considered as FIS input. The wavelet of db4 with the coefficient of determination (R) of 0.9979, RMSE of 0.0968, and mean recovery of 100.63% was chosen as the best one for the EE, while bior1.3 with R of 0.9955, RMSE of 0.4055, and mean recovery of 101.93% was selected for DP. These methods were successfully used to analyze the EE and DP simultaneously in tablet pharmaceutical formulation without any separation step. The suggested methods were compared with a reference method (HPLC) using analysis of variance (ANOVA) at a 95% confidence level, and no significant difference was observed in terms of accuracy. The suggested chemometric methods are reliable, rapid, and inexpensive, and can be used as an environmentally friendly alternative to HPLC for the simultaneous estimation of the mentioned drugs in commercial pharmaceutical products.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.saa.2024.124541 | DOI Listing |
Med Image Anal
January 2025
Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon, 440-746, South Korea. Electronic address:
This study introduces HCC-Net, a novel wavelet-based approach for the accurate diagnosis of hepatocellular carcinoma (HCC) from abdominal ultrasound (US) images using artificial neural networks. The HCC-Net integrates the discrete wavelet transform (DWT) to decompose US images into four sub-band images, a lesion detector for hierarchical lesion localization, and a pattern-augmented classifier for generating pattern-enhanced lesion images and subsequent classification. The lesion detection uses a hierarchical coarse-to-fine approach to minimize missed lesions.
View Article and Find Full Text PDFJ Zhejiang Univ Sci B
December 2024
Center for Cognition and Brain Disorders / Department of Neurology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou 311121, China.
White-matter tracts play a pivotal role in transmitting sensory and motor information, facilitating interhemispheric communication and integrating different brain regions. Meanwhile, sensorimotor disturbance is a common symptom in patients with major depressive disorder (MDD). However, the role of aberrant sensorimotor white-matter system in MDD remains largely unknown.
View Article and Find Full Text PDFComput Methods Programs Biomed
January 2025
Key Laboratory of Computer Network and Information Integration (Southeast University), Ministry of Education, Nanjing, China; School of Computer Science and Engineering, Southeast University, Nanjing, China.
Purpose: Dual-energy computed tomography (DECT) enables the differentiation of different materials. Additionally, DECT images consist of multiple scans of the same sample, revealing information similarity within the energy domain. To leverage this information similarity and address safety concerns related to excessive radiation exposure in DECT imaging, sparse view DECT imaging is proposed as a solution.
View Article and Find Full Text PDFMath Biosci Eng
December 2024
School of Information Engineering, Nantong Institute of Technology, Nantong 226002, Jiangsu, China.
As an essential component of mechanical systems, bearing fault diagnosis is crucial to ensure the safe operation of the equipment. However, vibration data from bearings often exhibit non-stationary and nonlinear features, which complicates fault diagnosis. To address this challenge, this paper introduces a novel multi-scale time-frequency and statistical features fusion model (MTSF-FM).
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Electronics and Communication Engineering, Rajiv Gandhi University, Rono Hills, Doimukh, ITANAGAR, Itanagar, Arunachal Pradesh, 791112, INDIA.
Accurate detection of cardiac arrhythmias is crucial for preventing premature deaths. The current study employs a dual-stage Discrete Wavelet Transform (DWT) and a median filter to eliminate noise from ECG signals. Subsequently, ECG signals are segmented, and QRS regions are extracted for further preprocessing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!