AI Article Synopsis

  • This study looked at how long it takes to remove IUDs that are in the wrong position compared to those that are in the right position.
  • Researchers found that IUDs that were mispositioned were taken out sooner and more often than those that were correctly placed.
  • Most IUDs, even the ones that were stuck or partly inside the body, were successfully taken out on the first try by doctors using a special tool called ring forceps.

Article Abstract

Objective: This study aimed to compare removal timing, techniques, and success of malpositioned intrauterine device (IUDs) to nonmalpositioned IUDs.

Study Design: We performed a retrospective cohort study of IUD users with ultrasound performed between July 2014 and July 2017 within one medical system. We used Fisher exact and Wilcoxon rank-sum tests to compare clinical characteristics and IUD removal details between patients with malpositioned and nonmalpositioned IUDs.

Results: Of 1759 ultrasounds reporting the presence of an IUD, 436 described IUD malposition. Of these, 150 described the IUD as embedded and 16 as partially perforated. IUDs were more likely to be removed and removed sooner for patients with malpositioned compared with nonmalpositioned IUDs (281/436 vs 545/1323, p < 0.001 and median 17 days vs 236 days from the index ultrasound, p < 0.001). Most IUDs, malpositioned and nonmalpositioned, were removed on the first attempt (82%, 85%), by a generalist obstetrician and gynecologist (75%, 70%), using a ring forceps (73%, 65%). Most embedded and partially perforated IUDs were removed (68%, 69%), using a ring forceps (59%, 67%), on the first attempt (84%, 91%).

Conclusions: Malpositioned IUDs were more likely to be removed and removed sooner than nonmalpositioned IUDs. Most IUDs, even IUDs labeled as partially perforated or embedded, were removed by a generalist obstetrician and gynecologist, using ring forceps, on first attempt.

Implications: Ultrasound findings of IUD malposition are not associated with difficult IUD removal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.contraception.2024.110504DOI Listing

Publication Analysis

Top Keywords

malpositioned intrauterine
8
retrospective cohort
8
cohort study
8
patients malpositioned
8
described iud
8
iud
5
ease removal
4
malpositioned
4
removal malpositioned
4
intrauterine devices
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!