A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Colonoscopy findings after increasing two-stool faecal immunochemical test (FIT) cut-off: Cross-sectional analysis of the SCREESCO randomized trial. | LitMetric

Background: We determined the impact of an increased two-stool faecal immunochemical test (FIT) cut-off on colonoscopy positivity and relative sensitivity and specificity in the randomized controlled screening trial screening of Swedish colons conducted in Sweden.

Methods: We performed a cross-sectional analysis of participants in the FIT arm that performed FIT between March 2014 and 2020 within the study registered with ClinicalTrials.gov, NCT02078804, who had a faecal haemoglobin concentration of at least 10 µg/g in at least one of two stool samples and who underwent a colonoscopy (n = 3841). For each increase in cut-off, we computed the positive predictive value (PPV), numbers needed to scope (NNS), sensitivity and specificity for finding colorectal cancer (CRC) and advanced neoplasia (AN; advanced adenoma or CRC) relative to cut-off 10 µg/g.

Results: The PPV for AN increased from 23.0% (95% confidence intervals [CI]: 22.3%-23.6%) at cut-off 10 µg/g to 28.8% (95% CI: 27.8%-29.7%) and 33.1% (95% CI: 31.9%-34.4%) at cut-offs 20 and 40 µg/g, respectively, whereas the NNS to find a CRC correspondingly decreased from 41 to 27 and 19. The PPV for AN was higher in men than women at each cut-off, for example 31.5% (95% CI: 30.1%-32.8%) in men and 25.6% (95% CI: 24.3%-27.0%) in women at 20 µg/g. The relative sensitivity and relative specificity were similar in men and women at each cut-off.

Conclusion: A low cut-off of around 20-40 µg/g allows detection and removal of many AN compared to 10 µg/g while reducing the number of colonoscopies in both men and women.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joim.13810DOI Listing

Publication Analysis

Top Keywords

men women
12
two-stool faecal
8
faecal immunochemical
8
immunochemical test
8
test fit
8
fit cut-off
8
cross-sectional analysis
8
relative sensitivity
8
sensitivity specificity
8
cut-off
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!