Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Therapeutic drug monitoring of pegylated L-asparaginase (ASNase) ensures the drug effectiveness in childhood acute lymphoblastic leukaemia (ALL) patients. The biological drug property with variable immunogenic host clearance, and the prescription of its generic formulation urge the need for a reliable assay to ensure an optimal treatment and improve outcome. This study aimed to optimise an existing isocratic reversed-phase high performance liquid chromatography (RP-HPLC) method with an automated pre-column sample derivatisation and injection program, and a computational algorithm for measuring serum pegylated ASNase activity in children with ALL. Nath et al.'s method in 2009 was adopted and modified using a pegylated ASNase. A set of Microsoft Excel macros was developed for the serum drug activity computation. An Agilent InfinityLab LC Series 1260 Infinity II Quaternary System with fluorescence detection was employed with an Agilent Poroshell 120 EC-C18 4.6×100 mm, 2.7 µm analytical column. System flow rate was optimised to 2.0 mL/min with 40×10/bar pump compressibility. The O-phthaldialdehyde (OPA) solution composition was optimised to 1 % o-phthaldialdehyde, 0.8 % 2-mercaptoethanol, 7.13 % methanol, and 1.81 % sodium tetraborate. The pre-column derivatisation program mixed 0.1 µL sample with 25 µL OPA solution before the automated injection. Method validation was according to the ICH guidelines. Total analysis time was 15 min, with L-aspartic acid eluted at 0.96 min and internal standard at 4.7 min. The calibration curves showed excellent linearity (R ≥0.9999). Interday precision for the drug activity at 0.1 IU/mL, 0.5 IU/mL, and 1 IU/mL were 4.15 %, 3.05 %, and 3.09 % (n = 6). Mean %error for the drug activity at 0.1 IU/mL, 0.5 IU/mL, and 1 IU/mL were 0.90±4.41 %, -1.37±3.04 %, and -3.03±3.02 % (n = 6). Limit of quantitation was 0.03 IU/mL. Majority of the patients' serum drug activity fell within the assay calibration range. Our improved method is automated, having shorter analysis time with a well-maintained separation resolution that enables a high-throughput analysis for application.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2024.116243 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!