Comparison of the axial growth with multifocal and monofocal intraocular lenses in unilateral pediatric cataract surgery.

Graefes Arch Clin Exp Ophthalmol

Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, China.

Published: December 2024

Purpose: To compare axial growth in pediatric cataract patients who underwent multifocal intraocular lens (IOL) implantation without anterior vitrectomy (AV) with that in pediatric patients who underwent monofocal IOL implantation with or without AV.

Methods: Patients who had unilateral pediatric cataracts and underwent surgery at 3-6 years of age from June 6, 2019, to June 30, 2020, at our institution were prospectively analyzed. The patients were categorized into Group A: multifocal IOL implantation with optic capture in Berger's space without AV; Group B: monofocal IOL implantation with optic capture in Berger's space without AV; and Group C: bag-in-the-lens monofocal IOL implantation with AV. Groups A', B' and C' consisted of the fellow eyes from the respective groups. Axial growth and monthly growth rates were compared among the 3 treatment groups, as well as between the treated eyes and the fellow eyes.

Results: Thirty-one, 23, and 14 children fulfilling the inclusion criteria, respectively, were included in the final analysis. There were no significant differences in patient age at the time of surgery or preoperative axial length (P > 0.05). After a mean follow-up of 35.57 ± 3.78 months, significant differences in the axial growth and the monthly growth rate were observed (P < 0.05), and Group A had the least axial elongation. Comparing treated eyes with fellow eyes, the amount and rate of axial growth were lower in Group A than in Group A' (P < 0.05), no significant differences were found in Group B (P > 0.05), and Group C had greater growth than did Group C' (P < 0.05).

Conclusions: The implanting multifocal intraocular lenses and maintenance of vitreous body integrity may be protective factors against excessive axial growth in pediatric cataract patients. Clinical trial registration (prospective study): chiCRT1900023155; 2019-05-14.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-024-06535-5DOI Listing

Publication Analysis

Top Keywords

iol implantation
20
axial growth
16
monofocal iol
12
unilateral pediatric
8
pediatric cataract
8
patients underwent
8
implantation optic
8
optic capture
8
capture berger's
8
berger's space
8

Similar Publications

Purpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.

Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively.

View Article and Find Full Text PDF

Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate visual outcomes and patient satisfaction after bilateral implantation of a new hydrophobic acrylic intraocular lens called Clareon (Alcon) using the mini-monovision technique.

Methods: A single-center, prospective, nonrandomized study was conducted in Tandil (Buenos Aires, Argentina), including patients scheduled for cataract surgery. To achieve mini-monovision, the spherical equivalent was calculated between -0.

View Article and Find Full Text PDF

We describe a novel experimental device, the VaMa (Vatavuk and Marić) artificial intraocular lens (IOL) capsule, and a method that enables all IOL types to be implanted in the bag. We present the application of the device and the procedure in patients with aphakia and native capsule damage and without efficient capsular support. The VaMa device and the method facilitate IOL exchange due to refractive errors and, in the case of their invention, the implementation of superior IOLs in the future.

View Article and Find Full Text PDF

Purpose: To compare the refractive accuracy of the Barrett True axial length (BTAL) formula, newly integrated into ARGOS, with that of the Barrett Universal II (BUII) formula calculated using axial length (AL) from IOL Master 700.

Setting: Private clinics in Kanagawa, Japan.

Design: Retrospective observational study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!