This is a case of an infant with duct-dependent pulmonary circulation, who required 6 stents delivered over three procedures to fully stent the arterial duct, which originated in a very unusual fashion. The attainable angiographic projections were unable to profile its origin, and only a CT scan was ultimately able to delineate the (stenotic) ductal origin from the aorta.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-024-03527-4DOI Listing

Publication Analysis

Top Keywords

pda stent
4
stent placement
4
placement high-impact
4
high-impact limitations
4
limitations angiography
4
angiography delineate
4
delineate complex
4
complex pda
4
pda case
4
case infant
4

Similar Publications

PDA stenting is increasingly utilized for patients with ductal-dependent pulmonary blood flow. Predicting optimal stent length prior to and during the intervention remains a challenge. The utility of pre-catheterization computed tomography angiography (CTA) to predict stent length was evaluated.

View Article and Find Full Text PDF

Objective: Berry syndrome is a group of rare congenital cardiac malformations including aortopulmonary window (APW), aortic origin of the right pulmonary artery (AORPA), interruption of the aortic arch (IAA), patent ductus arteriosus (PDA) (supplying the descending aorta) and intact ventricular septum. This paper will analyze the clinical data of 7 patients with Berry syndrome who underwent surgical treatment in our institution and discuss the one-stage surgical correction of Berry syndrome in combination with the literature.

Methods: From January 2013 to July 2024, a total of 7 children with Berry syndrome were admitted to the Cardiac Surgery Department of Beijing Children's Hospital.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the feasibility and effectiveness of using 3D printed models for treating congenital coarctation of the aorta (CoA) in adolescents and adults, involving 10 patients who underwent the procedure.
  • Results showed significant improvements post-treatment: the narrowest diameter of CoA increased from an average of 4.35 mm to 16.84 mm, and transconstrictive systolic pressure difference dropped from 81.29 mmHg to 15.52 mmHg.
  • The procedure was generally successful, but there were some complications during hospitalization and follow-up, particularly in patients with additional heart defects.
View Article and Find Full Text PDF

This article provides a historical review and a current perspective on the procedures used to palliate cyanosis in ductal-dependent infants. Eighty years ago, Helen Taussig, Alfred Blalock, and Vivien Thomas developed the first effective treatment. The Blalock-Taussig-Thomas (BTT) shunt is the historical predecessor of both the contemporary-modified BTT shunt and interventional stenting of the Patent Ductus Arteriosus (PDA).

View Article and Find Full Text PDF

This article provides a historical review and a current perspective on the procedures used to palliate cyanosis in ductal-dependent infants. Eighty years ago, Helen Taussig, Alfred Blalock and Vivien Thomas developed the first effective treatment. The Blalock-Taussig-Thomas (BTT) shunt is the historical predecessor of both the contemporary modified BTT shunt and interventional stenting of the Patent Ductus Arteriosus (PDA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!