This virtual study was designed to evaluate the stress-deformation of a metal fixed partial dentures (FPDs) pontic under different loads using two different connectors. The STL file was generated for a RPD of two implant-supported restorations. The Co-Cr metal substructure was designed with two types of connector design. The pontic is connected to implant-supported crowns with square and round shape connectors. This study was designed for a cementless-retained implant-supported FPD. Finite element modeling (FEM) is used to assess the stress and deformation of the pontic within a metal substructure as the FEM might provide virtual values that could have laboratory and clinical relevance. The Co-Cr alloy mechanical properties like the Poisson ratio and modulus of elasticity were based on the parameters of the three-dimensional structure additive method. Nonparametric analyses (Mann-Whitney U test) was used. The use of square or round connectors often resulted in non-significant changes in stress, and deformation under either three or each loaded point on the occlusal surface of a pontic (P > 0.05). However, the deformation revealed distinct variations between loads of the three points compared to each loaded point (P ≤ 0.05). According to this study data, the pontic occlusal surface appears to be the same in stress and deformation under different loads depending on whether square or round connectors are used. While at the same connector designs, the pontic occlusal surface deformed significantly at three loaded points than it did at each point.

Download full-text PDF

Source
http://dx.doi.org/10.1615/JLongTermEffMedImplants.2023048378DOI Listing

Publication Analysis

Top Keywords

square round
12
stress deformation
12
occlusal surface
12
finite element
8
connector designs
8
designs pontic
8
fixed partial
8
study designed
8
metal substructure
8
round connectors
8

Similar Publications

Introduction: Fluid overload (FO), a state of pathologic positive cumulative fluid balance (CFB), is common in Pediatric Intensive Care Units (PICU) and associated with morbidity and mortality. Because different PICUs may have unique needs, barriers, and limitations to accurately report fluid balance (FB) and reduce FO, understanding the drivers of positive FB is needed. We hypothesize CFB >5% and >10% is common within initial days of PICU admission, but that reasons for high %CFB will vary across sites, as will barriers to accurate FB recording and opportunities to improve FB recording and management.

View Article and Find Full Text PDF

Several mechanisms were postulated to reduce drilling problems, improve hole cleaning characteristics, and keep the bit in good condition for the second usage. This study was conducted on Majnoon Field in southeastern Iraq to optimize the bit and drilling parameters. The results indicated that the 16" SFD75D bit proved the preferred bit for both vertical and deviated wells due to its directional capabilities.

View Article and Find Full Text PDF

Serious illness conversation (SIC) in an important skillset for clinicians. A review of mortality meetings from an urban academic hospital highlighted the need for early engagement in SICs and advance care planning (ACP) to align medical treatments with patient-centered outcomes. The aim of this study was to increase SICs and their documentation in patients with low one-year survival probability identified by updated Charlson Comorbidity Index (CCI) scores.

View Article and Find Full Text PDF

Introduction: Although there are acceptable medical reasons for the use of food supplements, most prescriptions for newborns do not comply with current recommendations, putting continued breastfeeding at risk. This study aimed to create and validate a flowchart for newborn supplement prescription.

Methods: The flowchart was created and submitted to two rounds of assessments by a panel of judges, who calculated the content validity index (CVI) (acceptable > 0.

View Article and Find Full Text PDF

Background: Activity level is a benchmark to document patient recovery; however, there is a lack of instrumentation to measure activity level specific to the foot and ankle. The purpose of this study was to develop a foot and ankle activity level scale (FAALS) instrument that will serve as an effective clinical tool for practitioners by assigning an activity level to patients.

Methods: This was a 4-phase study with 3 rounds of data collection (n = 1432).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!