Background: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking.

Aims: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO.

Methods: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability.

Results: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved.

Conclusions: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11145311PMC
http://dx.doi.org/10.4244/EIJ-D-23-00802DOI Listing

Publication Analysis

Top Keywords

left atrial
16
atrial appendage
12
cardiac computed
8
computed tomography
8
appendage occlusion
8
laao performed
8
amplatzer amulet
8
amulet device
8
laa sealing
8
complete occlusion
8

Similar Publications

Impact of percutaneous left atrial appendage occlusion on the severity of ischemic stroke.

Cardiovasc Revasc Med

December 2024

Division of Cardiovascular Medicine, University of Toledo Medical Center, Toledo, OH, United States of America. Electronic address:

Background: Percutaneous left atrial appendage occlusion (pLAAO) presents an alternative to anticoagulation (AC) for stroke prophylaxis in atrial fibrillation (Afib) patients with high bleeding risk. pLAAO was associated with lower rates of disabling stroke which was mainly attributed to the reduction of hemorrhagic stroke (HS). Little is known about the impact of pLAAO on the severity of ischemic strokes which we sought to study.

View Article and Find Full Text PDF

Left atrial strain (LAS) was recently introduced as a parameter that reflects on left atrial function. Consequently, changes in LAS can inform the development of cardiovascular diseases, hence providing a window for non-invasive and cost-effective testing of these diseases and their complications at early stages of development, potentially offering a segway towards preventive interventions. LAS has yet to be implemented into standard practice.

View Article and Find Full Text PDF

Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).

View Article and Find Full Text PDF

Increasing evidence has demonstrated that sPRR [a truncated soluble form of (pro)renin receptor] levels may reflect the severity of several diseases, including kidney disease, hypertension, and heart failure (HF). Although previous studies using cohorts primarily consisting of HF patients with reduced ejection fraction revealed that increased plasma sPRR levels may be a promising evaluative indicator for HF, definitive information on the relationship between plasma sPRR levels and HF patients with preserved ejection fraction (HFpEF) is still insufficient and scarce. In the present study, we further clarified the status of plasma sPRR levels in HF patients by meta-analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!