In silico intravascular optical coherence tomography (IVOCT) for quality assured imaging with reduced intervention.

Sci Rep

School of Chemical and Environmental Engineering, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.

Published: June 2024

In the clinical application of intravascular optical coherence tomography (IVOCT), it is necessary to flush opaque blood during image acquisition. However, there are no specific standards for how to perform low-dose but effective flushing. In this study, computational fluid dynamics (CFD) and optical models were integrated to numerically simulate the complete process of IVOCT, which includes blood flushing with normal saline followed by image acquisition. Moreover, an intermittent injection scheme was proposed, and its advantages over the conventionally adopted scheme of continuous injection were verified. The results show that intermittent injection can significantly reduce the dosage of normal saline (reduced by 44.4%) with only a slight sacrifice of image quality (reduced by 8.7%, but still acceptable). The developed model and key findings in this work can help surgeons practice optimized IVOCT operations and potentially lead to improved designs of the IVOCT equipment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11153535PMC
http://dx.doi.org/10.1038/s41598-024-61177-1DOI Listing

Publication Analysis

Top Keywords

intravascular optical
8
optical coherence
8
coherence tomography
8
tomography ivoct
8
image acquisition
8
normal saline
8
intermittent injection
8
ivoct
5
silico intravascular
4
ivoct quality
4

Similar Publications

A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.

View Article and Find Full Text PDF

Background: Acute promyelocytic leukemia (APL) is characterized by abnormal promyelocytes and t(15;17)(q24;q21) . Rarely, patients may have cryptic or variant rearrangements. All-trans retinoic acid (ATRA)/arsenic trioxide (ATO) is largely curative provided that the diagnosis is established early.

View Article and Find Full Text PDF

Intravascular Imaging as a Performance Measure for Percutaneous Coronary Intervention.

Circ Cardiovasc Interv

January 2025

Division of Cardiology, Department of Medicine, University of Washington Medical Center, Seattle (E.J.S., T. Salahuddin, J.A.D.).

Background: Intravascular imaging (IVI) is widely recognized to improve outcomes after percutaneous coronary intervention (PCI). However, IVI is underutilized and is not yet established as a performance measure for quality PCI.

Methods: We examined temporal trends of IVI use for all PCIs performed at Veterans Affairs hospitals in the United States from 2010 to 2022 using retrospective observational cohorts.

View Article and Find Full Text PDF

Objective: This study aimed to elucidate the clinical manifestations, laboratory findings and outcomes of patients with intravascular large B cell lymphoma (IVLBCL) with neurological involvement and to differentiate IVLBCL with and without neurological involvement.

Methods: A cohort study was conducted at Siriraj Hospital, Mahidol University, Thailand, between January 2005 and September 2024. Clinical data, laboratory values and central nervous system imaging results were analysed.

View Article and Find Full Text PDF

Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.

Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.

View Article and Find Full Text PDF