A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Off-pump coronary artery bypass grafting with clampless aortic anastomosis devices: Aortic sealing devices versus automated anastomosis punching. | LitMetric

Objectives: Clampless aortic anastomosis devices aim to lower stroke risk in off-pump coronary artery bypass grafting. Two main strategies for clampless anastomosis devices emerged with automated anastomosis punching and aortic sealing devices, prompting the question of perioperative outcome differences.

Methods: All consecutive patients undergoing elective off-pump coronary artery bypass grafting with a clampless aortic anastomosis device between September 2014 and December 2021 in 2 centers were retrospectively included. Cohorts were divided by the use of an automated anastomosis punching device or an aortic sealing device to achieve proximal anastomosis on the ascending aorta. To reach group comparability propensity score matching was performed. The primary end point was defined as a composite of all-cause mortality, stroke and rethoracotomy. Secondary end points were perioperative outcome parameters.

Results: A total of 3703 patients were enrolled of whom 575 and 3128 were included in the automated anastomosis punching and the aortic sealing device group, respectively. By propensity score matching a total of 1150 patients were included with 575 in each group. The primary composite endpoint showed no significant difference with 6.3% versus 5.9% events (odds ratio, 0.9; 95% confidence interval, 0.58-1.53,  = .81). All-cause mortality ( = .36), stroke ( = .81), and rethoracotomy ( = .89) also exhibit no disparity. Operation time was significantly longer in the aortic sealing device cohort with 220.0 ± 50.8 minutes and 204.6 ± 53.8 minutes ( < .01).

Conclusions: Clampless aortic anastomosis strategies aortic sealing device and automated anastomosis punching did not differ in perioperative outcome parameters, whereas the implementation of aortic sealing devices were associated with a prolonged operation time without inducing any inferior clinical outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11145195PMC
http://dx.doi.org/10.1016/j.xjtc.2024.01.010DOI Listing

Publication Analysis

Top Keywords

aortic sealing
20
automated anastomosis
16
anastomosis punching
16
off-pump coronary
12
coronary artery
12
artery bypass
12
bypass grafting
12
clampless aortic
12
aortic anastomosis
12
anastomosis devices
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!