Objective:  The aim of this study was to measure the mechanical properties and failure mode of an model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate.

Study Design:  Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking. Single-cycle axial compression testing was conducted until failure. The frequency of implant plastic deformation was recorded. Bone failure analysis was performed through computed tomography examinations and fractal analysis.

Results:  There were no differences in the analysed mechanical variables and fractal dimension among the groups. Transarticular screws showed a higher frequency of deformation (75%) regardless of the group. Both unicortical locking and bicortical locking groups deformed the plate more frequently.

Conclusion:  The type of screw used in the proximal hole of the locking compression plate and its method of anchoring in the proximal phalanx do not affect the mechanical properties of pastern arthrodesis in equine cadavers subjected to single-cycle axial compression tests until failure.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0044-1787680DOI Listing

Publication Analysis

Top Keywords

locking compression
16
mechanical properties
12
proximal screw
12
compression plate
12
properties failure
8
failure mode
8
screw fixation
8
locking
8
proximal interphalangeal
8
interphalangeal arthrodesis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!