A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of a portable lower-limb muscle strength measuring device with a training function. | LitMetric

AI Article Synopsis

  • Quadriceps muscle strength is important for daily activities, leading to the development of the LocomoScan (LCS), a new compact device for measuring lower limb muscle strength.
  • A study involving 104 healthy university students compared LCS with traditional devices, assessing its simplicity, reproducibility, and accuracy in measuring knee extension force and muscle mass.
  • Results showed LCS had high reproducibility in measurements and a significant relationship between knee extension force and muscle mass, confirming it as a practical tool for assessing muscle strength in clinical settings.

Article Abstract

[Purpose] Quadriceps muscle strength is essential for daily living activities. Therefore, we developed a compact and simple lower limb muscle strength measuring device (LocomoScan [LCS]). This study aimed to compare LCS with other instruments to analyze its simplicity, reproducibility, and accuracy. [Participants and Methods] One hundred and four healthy university students (56 males and 48 females) were included in the study. The knee extension force was measured using LCS, and the knee extension torque was measured using other devices (Cybex). In addition, lower leg muscle mass was measured using a body composition meter. The reproducibility of LCS and the correlation between the knee extension torque and lower leg muscle mass were evaluated. [Results] The measurement reproducibility of LCS was significantly higher. The knee extension force confirmed the proportional relative reliability of Cybex with knee extension torque. A relationship between knee extension force and lower limb muscle mass was also observed, indicating that muscle mass cannot be estimated as muscle strength. [Conclusion] The high reproducibility of the knee extension force measurement using LCS demonstrates its potential as a portable alternative instrument for muscle strength measurement in clinical practice. Therefore, LCS device is a simple and effective tool for assessing muscle strength.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11144476PMC
http://dx.doi.org/10.1589/jpts.36.343DOI Listing

Publication Analysis

Top Keywords

knee extension
28
muscle strength
24
extension force
16
muscle mass
16
extension torque
12
muscle
10
strength measuring
8
measuring device
8
lower limb
8
limb muscle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!