Accurately determining and classifying different types of skin cancers is critical for early diagnosis. In this work, we propose a novel use of deep learning for classification of benign and malignant skin lesions using dermoscopy images. We obtained 770 de-identified dermoscopy images from the University of Missouri (MU) Healthcare. We created three unique image datasets that contained the original images and images obtained after applying a hair removal algorithm. We trained three popular deep learning models, namely, ResNet50, DenseNet121, and Inception-V3. We evaluated the accuracy and the area under the curve (AUC) receiver operating characteristic (ROC) for each model and dataset. DenseNet121 achieved the best accuracy (80.52%) and AUC ROC score (0.81) on the third dataset. For this dataset, the sensitivity and specificity were 0.80 and 0.81, respectively. We also present the SHAP (SHapley Additive exPlanations) values for the predictions made by different models to understand their interpretability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11141796PMC