Background: PortionSize offers real-time feedback on dietary intake, including intake of MyPlate food groups but requires further evaluation on a larger sample in a laboratory-based setting. MyFitnessPal (MFP) is a commonly used commercial dietary assessment application, and to our knowledge, no known studies have evaluated MFP in a laboratory setting.

Objectives: The overall objective was to test the validity of PortionSize and MFP to accurately measure intake compared with that of weighed food (WB) and to compare error between applications. A secondary objective was to test usability, satisfaction, and user preference between applications.

Methods: This randomized crossover study was completed between February and October 2021. Participants (N = 43) used both applications to estimate intake in a laboratory setting. Participants were provided with a preweighed plated meal and plated leftovers. Two 1-sided t tests assessed equivalence (±21% bounds) between simulated intake from PortionSize and WB, and MFP and WB. The primary outcome was energy intake, and secondary outcome measures were portion size (in grams), food groups, and other nutrients. Differences in relative absolute error, usability, satisfaction, and user preference between applications were evaluated using dependent samples t tests. Cohen d assessed effect size.

Results: For PortionSize, energy and portion size were underestimated by 13.3% and 14.0%, respectively, and were not equivalent to WB. For MFP, energy was overestimated by 7.0%, and equivalent to WB (P = 0.04). Relative absolute error for energy did not differ between applications. For PortionSize, Cohen d was small (<0.2) for fruits, grains, protein foods, and specific nutrients. No differences were seen with usability, and the only difference for satisfaction was that participants found it easier to use MFP to find foods consumed (P = 0.019), and participants preferred using MFP (P = 0.014).

Conclusions: PortionSize requires further updates to improve energy estimates and usability but demonstrates clinical utility for tracking food group and nutrient intake. PortionSize did not outperform MFP for measuring energy intake.

Clinical Trial Registry: This trial was registered at clinicaltrials.gov as NCT04700904 (https://classic.

Clinicaltrials: gov/ct2/show/NCT04700904).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11347805PMC
http://dx.doi.org/10.1016/j.ajcnut.2024.05.023DOI Listing

Publication Analysis

Top Keywords

validity portionsize
8
randomized crossover
8
food groups
8
objective test
8
portionsize mfp
8
usability satisfaction
8
satisfaction user
8
user preference
8
portion size
8
relative absolute
8

Similar Publications

Objective: Evaluate the validity of the PortionSize application.

Methods: In this pilot study, 14 adults used PortionSize to record their free-living food intake over 3 consecutive days. Digital photography was the criterion measure, and the main outcomes were estimated intake of food (grams), energy (kilocalories), and food groups.

View Article and Find Full Text PDF

Background: PortionSize offers real-time feedback on dietary intake, including intake of MyPlate food groups but requires further evaluation on a larger sample in a laboratory-based setting. MyFitnessPal (MFP) is a commonly used commercial dietary assessment application, and to our knowledge, no known studies have evaluated MFP in a laboratory setting.

Objectives: The overall objective was to test the validity of PortionSize and MFP to accurately measure intake compared with that of weighed food (WB) and to compare error between applications.

View Article and Find Full Text PDF

Background: Important gaps exist in the dietary intake of adolescents in low- and middle-income countries (LMICs), partly due to expensive assessment methods and inaccuracy in portion-size estimation. Dietary assessment tools leveraging mobile technologies exist but only a few have been validated in LMICs.

Objective: We validated Food Recognition Assistance and Nudging Insights (FRANI), a mobile artificial intelligence (AI) dietary assessment application in adolescent females aged 12-18 y (n = 36) in Ghana, against weighed records (WR), and multipass 24-hour recalls (24HR).

View Article and Find Full Text PDF

Background: There is a gap in data on dietary intake of adolescents in low- and middle-income countries (LMICs). Traditional methods for dietary assessment are resource intensive and lack accuracy with regard to portion-size estimation. Technology-assisted dietary assessment tools have been proposed but few have been validated for feasibility of use in LMICs.

View Article and Find Full Text PDF

Background: Accurately assessing dietary intake can promote improved nutrition. The PortionSize app (Pennington Biomedical Research Center) was designed to quantify and provide real-time feedback on the intake of energy, food groups, saturated fat, and added sugar.

Objective: This study aimed to assess the preliminary feasibility and validity of estimating food intake via the PortionSize app among adults.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!