A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stem anteversion is not affected by proximal femur geometry in robotic-assisted total hip arthroplasty. | LitMetric

Stem anteversion is not affected by proximal femur geometry in robotic-assisted total hip arthroplasty.

Arthroplasty

Department of Orthopaedic Surgery, Azienda Ospedaliero-Universitaria Policlinico di Modena, University of Modena and Reggio-Emilia, Via del Pozzo 71, Modena, MO, 41125, Italy.

Published: June 2024

Background: In the present study, the surgeon aimed to align the stem at 5° to 25° in anteversion. The robotic technology was used to measure stem anteversion with respect to proximal femur anteversion at different levels down the femur.

Methods: A total of 102 consecutive patients underwent robotic-arm-assisted total hip arthroplasty (RTHA). 3D CT-based preoperative planning was performed to determine femoral neck version (FNV), posterior cortex anteversion (PCA), anterior cortex anteversion (ACA), and femoral metaphyseal axis anteversion (MAA) at 3 different levels: D (10 mm above lesser trochanter), E (the midpoint of the planned neck resection line) and F (head-neck junction). The robotic system was used to define and measure stem anteversion during surgery.

Results: Mean FNV was 6.6° (SD: 8.8°) and the mean MAA was consistently significantly higher than FNV, growing progressively from proximal to distal. Mean SV was 16.4° (SD: 4.7°). There was no statistically significant difference (P = 0.16) between SV and MAA at the most distal measured level. In 96.1% cases, the stem was positioned inside the 5°-25° anteversion range.

Conclusions: Femoral anteversion progressively increased from neck to proximal metaphysis. Aligning the stem close to femoral anteversion 10 mm above the lesser trochanter often led to the desired component anteversion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11144328PMC
http://dx.doi.org/10.1186/s42836-024-00248-0DOI Listing

Publication Analysis

Top Keywords

stem anteversion
12
anteversion
11
proximal femur
8
total hip
8
hip arthroplasty
8
measure stem
8
cortex anteversion
8
10 mm lesser
8
lesser trochanter
8
femoral anteversion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!