We demonstrate mid-infrared time-domain optical coherence tomography (OCT) with an orientation-patterned GaP optical parametric oscillator. Instantaneous broadband mid-infrared spectra provide reduced scattering for OCT applications including cultural heritage, quality assurance, and security. B-scan calibrations performed across the wavelength tuning range show depth resolutions of 67 µm at 5.1 µm and 88 µm at 10.5 µm. Volumetric imaging inside a plastic bank card is demonstrated at 5.1 µm, with a 1 Hz A-scan rate that indicates the potential of stable broadband OPO sources to contribute to mid-infrared OCT.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.520734DOI Listing