Background And Objective: Prostate Imaging for Recurrence Reporting (PI-RR) was introduced in 2021 to standardize the interpretation and reporting of multiparametric magnetic resonance imaging (MRI) for prostate cancer following whole-gland treatment. The system scores image on a scale from 1 to 5 and has shown promising results in single-center studies. The aim of our systematic review and meta-analysis was to assess the diagnostic performance of the PI-RR system in predicting the likelihood of local recurrence after whole-gland treatment.

Methods: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for diagnostic test accuracy were followed. Relevant databases were searched up to December 2023. Primary studies met the eligibility criteria if they reported MRI diagnostic performance in prostate cancer recurrence using PI-RR. Diagnostic performance for MRI was assessed using two different cutoff points (≥3 or ≥4 for positivity according to the PI-RR system). A meta-analysis with a random-effects model was used to estimate pooled sensitivity and specificity values.

Key Findings And Limitations: Sixteen articles were identified for full-text reading, of which six were considered eligible, involving a total of 467 patients. Using a cutoff of PI-RR ≥3 (4 studies) for recurrent disease, the sensitivity was 77.8% (95% confidence interval [CI] 69.9-84.1%) and the specificity was 80.2% (95% CI 58.2-92.2%). Using a cutoff of PI-RR ≥4 (4 studies), the sensitivity was 61.9% (95% CI 35.6-82.7%) and the specificity was 86.6% (95% CI 75.1-93.3%). Overall, the inter-rater agreement varied from fair to excellent.

Conclusions And Clinical Implications: PI-RR is accurate in detecting local recurrence after whole-gland treatment for prostate cancer and shows fair-to-good to excellent inter-reader agreement. Overall, a PI-RR cutoff of ≥3 showed high sensitivity and specificity.

Patient Summary: We reviewed studies that reported on how good MRI scans using a scoring system called PI-RR were in detecting recurrence of prostate cancer. We found that this system shows good performance, with fair to excellent agreement between different radiologists.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.euo.2024.05.007DOI Listing

Publication Analysis

Top Keywords

prostate cancer
20
diagnostic performance
12
pi-rr
10
prostate
8
magnetic resonance
8
resonance imaging
8
prostate imaging
8
imaging recurrence
8
recurrence reporting
8
reporting pi-rr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!