This study investigated the test-retest reliability of running economy (RE) and metabolic and cardiorespiratory parameters related to endurance running performance using a multistage incremental treadmill test. On two occasions separated by 21-28 days, 12 male middle- and long-distance runners ran at 10, 11, 12, 13, and 14 km/hr for 8 min each stage, immediately followed by a ramp test to volitional exhaustion. Carbohydrate (10% maltodextrin solution) was consumed before and during the test to provide ∼1 g/min of exercise. RE, minute ventilation (V˙E), oxygen consumption (V˙O2), carbon dioxide production (V˙CO2), respiratory exchange ratio (RER), heart rate (HR), ratings of perceived exertion (RPE), and blood glucose and lactate concentrations were recorded for each stage and at volitional exhaustion. Time-to-exhaustion (TTE) and peak oxygen consumption (V˙O2peak) during the ramp test were also recorded. Absolute reliability, calculated as the coefficient of variation (CV) between repeated measures, ranged from 2.3% to 3.1% for RE, whereas relative reliability, calculated as the intraclass correlation coefficient (ICC), ranged from .42 to .79. V˙E, V˙O2, V˙O2peak, V˙CO2, RER, and HR had a CV of 1.1%-4.3% across all stages. TTE and RPE had a CV of 7.2% and 2.3%-10.8%, respectively, while glucose and lactate had a CV of 4.0%-17.8%. All other parameters, except for blood glucose, were demonstrated to have good-to-excellent relative reliability assessed by ICC. Measures of RE, V˙O2peak, and TTE were reliable during this two-phase multistage incremental treadmill test in a cohort of trained and highly trained male middle- and long-distance runners.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijsnem.2023-0272DOI Listing

Publication Analysis

Top Keywords

multistage incremental
12
incremental treadmill
12
treadmill test
12
male middle-
12
middle- long-distance
12
long-distance runners
12
test-retest reliability
8
reliability running
8
running economy
8
economy metabolic
8

Similar Publications

Background: While the effectiveness of patient-reported outcome measures (PROMs) as an intervention to impact patient pathways has been established for cancer care, it is unknown for other indications. We assessed the cost-effectiveness of a PROM-based monitoring and alert intervention for early detection of critical recovery paths following hip and knee replacement.

Methods And Findings: The cost-effectiveness analysis (CEA) is based on a multicentre randomised controlled trial encompassing 3,697 patients with hip replacement and 3,110 patients with knee replacement enrolled from 2019 to 2020 in 9 German hospitals.

View Article and Find Full Text PDF

Assessing generalizability of an AI-based visual test for cervical cancer screening.

PLOS Digit Health

October 2024

Clinical Epidemiology Unit, Clinical Genetics Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, United States of America.

A number of challenges hinder artificial intelligence (AI) models from effective clinical translation. Foremost among these challenges is the lack of generalizability, which is defined as the ability of a model to perform well on datasets that have different characteristics from the training data. We recently investigated the development of an AI pipeline on digital images of the cervix, utilizing a multi-heterogeneous dataset of 9,462 women (17,013 images) and a multi-stage model selection and optimization approach, to generate a diagnostic classifier able to classify images of the cervix into "normal", "indeterminate" and "precancer/cancer" (denoted as "precancer+") categories.

View Article and Find Full Text PDF

Objective: Passive stiffness, a biomechanical parameter, has a potential influence on running economy, thus playing a pivotal role in performance. This study aimed to quantify passive stiffness of the Achilles tendon and gastrocnemius muscle using myotonometry throughout an incremental running protocol.

Methods: Twenty-one male participants underwent a multistage incremental test (Bordeaux test) on a treadmill until exhaustion.

View Article and Find Full Text PDF

This study investigated the test-retest reliability of running economy (RE) and metabolic and cardiorespiratory parameters related to endurance running performance using a multistage incremental treadmill test. On two occasions separated by 21-28 days, 12 male middle- and long-distance runners ran at 10, 11, 12, 13, and 14 km/hr for 8 min each stage, immediately followed by a ramp test to volitional exhaustion. Carbohydrate (10% maltodextrin solution) was consumed before and during the test to provide ∼1 g/min of exercise.

View Article and Find Full Text PDF

Background: Ensuring regular supervision, capacity building and motivation are crucial for the successful retention of health extension workers (HEWs). Failure in these aspects could increase the attrition rate of HEWs. To date, there has not been a comprehensive nationwide study on HEW attrition that could act as a source of evidence for policy makers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!