Tilt-series-based joint CTF estimation for cryo-electron tomography.

Structure

Key Laboratory for Protein Sciences of Ministry of Education, School of Life Sciences, Tsinghua University, Beijing 100084, China; State Key Laboratory of Membrane Biology, School of Life Sciences, Tsinghua University, Beijing 100084, China; Tsinghua-Peking Joint Center for Life Sciences, Beijing 100084, China; Beijing Frontier Research Center for Biological Structure, Beijing 100084, China; School of Life Sciences, Tsinghua University, Beijing 100084, China. Electronic address:

Published: August 2024

AI Article Synopsis

  • CTF estimation is crucial for obtaining high-resolution structures in cryo-electron tomography (cryoET), but challenges arise due to low signal quality and varying defocus in images.
  • The new software CTFMeasure implements a joint estimation method that enhances accuracy by utilizing Thon-ring signals from the entire tilt series.
  • CTFMeasure effectively estimates CTF parameters and tilt angle offsets for each micrograph, showing reliable results in both synthetic and real data tests.

Article Abstract

Contrast transfer function (CTF) estimation is a necessary step in the cryo-electron tomography (cryoET) workflow and essential for high-resolution in situ structural determination. However, the low signal-to-noise ratio and continuous defocus variation in micrographs of cryoET tilt series make accurate CTF estimation challenging. Here, we report a tilt-series-based joint CTF estimation method implemented in the new software CTFMeasure. The joint estimation method combines all Thon-ring signals in a tilt series to improve the estimation accuracy. By using an objective function involving the CTF parameters and geometric parameters of a cryoET tilt series, CTFMeasure can estimate the CTF parameters of each micrograph and the absolute tilt angle offset of the lamellar sample relative to the sample stage plane, which is usually the glancing angle used during focused ion beam (FIB) milling. Tests on both synthetic and experimental data, as well as subtomogram averaging, demonstrated the accurate CTF estimation of cryoET tilt series by CTFMeasure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.str.2024.05.006DOI Listing

Publication Analysis

Top Keywords

ctf estimation
20
tilt series
16
cryoet tilt
12
tilt-series-based joint
8
joint ctf
8
cryo-electron tomography
8
accurate ctf
8
estimation method
8
ctf parameters
8
series ctfmeasure
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!