The application of the golden-angle radial sparse parallel technique in T restaging of locally advanced rectal cancer after neoadjuvant chemoradiotherapy.

Abdom Radiol (NY)

Department of MR Scientific Marketing, Siemens Healthineers, Shanghai, 200135, People's Republic of China.

Published: August 2024

Purpose: To evaluate the diagnostic performance of Golden-Angle Radial Sparse Parallel (GRASP) MRI in identifying pathological stage T0-1 (ypT0-1) after neoadjuvant chemoradiotherapy (nCRT) in patients with rectal cancer, compared to T2-weighted imaging (T2WI) combined with Diffusion Weighted Imaging (DWI).

Methods: In this retrospective study, 168 patients were carefully selected based on inclusion criteria that targeted individuals with biopsy-confirmed primary rectal adenocarcinoma, identified via MRI as having locally advanced disease (≥ T3 and/or positive lymph node results) prior to nCRT. Post-nCRT, all MRI images obtained after nCRT were assessed by two observers independently. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for identifying ypT0-1 based on GRASP and T2 + DWI were calculated. Multivariable regression analysis was used to explore the factors independently associated with ypT0-1 tumor.

Results: 45 patients out of these cases were ypT0-1, and the accuracy, sensitivity, specificity, PPV, and NPV of GRASP were higher than the T2 + DWI (88% vs 74%, 93% vs 71%, 86% vs 75%, 71% vs 52% and 97% vs 88%), the AUC in identifying ypT0-1 tumor based on GRASP was 0.90 (95% CI:0.84, 0.94), which was better than the T2 + DWI (0.73; 95% CI: 0.66, 0.80). Multivariable logistic regression analysis showed that the yT stage on GRASP scans was the only factor independently associated with ypT0-1 tumor (P < 0.001).

Conclusion: The GRASP helped distinguish ypT0-1 tumor after nCRT and can select patients who may be suitable for local excision.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00261-024-04400-xDOI Listing

Publication Analysis

Top Keywords

golden-angle radial
8
radial sparse
8
sparse parallel
8
locally advanced
8
rectal cancer
8
neoadjuvant chemoradiotherapy
8
sensitivity specificity
8
identifying ypt0-1
8
based grasp
8
regression analysis
8

Similar Publications

Unsupervised reconstruction of accelerated cardiac cine MRI using neural fields.

Comput Biol Med

December 2024

Millennium Nucleus for Applied Control and Inverse Problems, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.

Background: Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization approaches that exploit spatial-temporal redundancy have been proposed to reconstruct undersampled cardiac cine MRI. More recently, methods based on supervised deep learning have been also proposed to further accelerate acquisition and reconstruction.

View Article and Find Full Text PDF

Background And Objectives: Vestibular schwannomas demonstrate different responses after stereotactic radiosurgery (SRS), commonly including a transient loss of internal enhancement on postcontrast T1-weighted MRI thought to be due to an early reduction in tumor vascularity. We used dynamic contrast-enhanced based golden-angle radial sparse parallel (GRASP) MRI to characterize the vascular permeability changes underlying this phenomenon, with correlations to long-term tumor regression.

Methods: Consecutive patients with vestibular schwannoma who underwent SRS between 2017 and 2019, had a transient loss of enhancement after SRS, and had long-term longitudinal GRASP studies (6, 18, and 30 months) were included in this retrospective cohort analysis (n = 19).

View Article and Find Full Text PDF

Purpose: Electrocardiography (ECG) and respiratory-gated preclinical cardiac CEST-MRI acquisitions are difficult because of variable saturation recovery with T, RF interference in the ECG signal, and offset-to-offset variation in Z-magnetization and cardiac phase introduced by changes in cardiac frequency and trigger delays.

Methods: The proposed method consists of segmented saturation modules with radial FLASH readouts and golden angle progression. The segmented saturation blocks drive the system to steady-state, and because center k-space is sampled repeatedly, steady-state saturation dominates contrast during gridding and reconstruction.

View Article and Find Full Text PDF

Background: Time-resolved angiography with interleaved stochastic trajectories (TWIST) magnetic resonance angiography (MRA) may obscure smaller vessels and is highly susceptibility to motion artifacts, potentially reducing endoleak detection accuracy after endovascular aortic repair (EVAR). The novel golden-angle radial sparse parallel (GRASP) sequence enhances spatial and temporal resolution with continuous, motion-robust datasets, showing promise for accurate endoleak detection post-EVAR. This study aimed to compare the diagnostic effectiveness of contrast-enhanced compressed-sensing radial GRASP-volume interpolated breath-hold examination (VIBE) sequence with standard contrast-enhanced dynamic TWIST-VIBE sequence in patients with inconclusive computed tomography angiography (CTA) findings regarding endoleak after EVAR.

View Article and Find Full Text PDF
Article Synopsis
  • This study compares two MRI techniques, TWIST and GRASP, for imaging aortic diseases, focusing on their effectiveness in dealing with patient movement.
  • It involved 30 patients and assessed the image quality of vascular structures, with GRASP showing better contrast and sharpness than TWIST, which is sensitive to motion artifacts.
  • Results indicated that GRASP provided clearer images and more accurate measurements of aortic diameters compared to TWIST, despite some increased streaking artifacts in GRASP images.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!