Introduction: Field tests are commonly used as complements of cardiopulmonary exercise test (CPET) to evaluate the functional exercise capacity. The aims of this study were to validate the one-minute sit-to-stand test (STST) in congenital heart disease (CHD) children and to evaluate the possibility of predicting the peakVO using the STST in this paediatric population.
Methods: Children (8- to 18-year-old) followed for a CHD and performing CPET were recruited prospectively. Concomitantly, they performed STST. The heart rate (HR), oxygen saturation (SpO), muscular fatigue and dyspnoea were recorded before (t0), immediately after (t1) and 1min after the end of the STST (t2).
Results: We observed a poor but significant correlation between the STST and the peakVO (r=0.306; p=0.013). A significant difference between girls and boys were observed for peakVO (p<0.001), HR t0 (p=0.030), HR t1 (p=0.002) and HR t2 (p<0.001). The proposed model of prediction, including the number of STST, weight, height and age explains 37% of the predicted peakVO variance.
Conclusion: The STST can provide relevant data on physical capacity in children with CHD. When CPET cannot be performed, we therefore propose an alternative equation using the STST as a surrogate of peakVO in CHD children.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arbres.2024.05.008 | DOI Listing |
Int J Cardiol
December 2024
Hacettepe University, Faculty of Physical Therapy and Rehabilitation, Department of Cardiorespiratory Physiotherapy and Rehabilitation, Turkey. Electronic address:
Respir Investig
December 2024
Department of Respirology, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan.
Background: Functional exercise capacity in pulmonary hypertension (PH) is routinely assessed using the 6-min walking test (6MWT). However, alternative tests are useful because of resource requirements. This study aimed to evaluate whether the 1-min sit-to-stand test (1STST) is useful and safe in PH and whether it can replace the 6MWT.
View Article and Find Full Text PDFBiomedicines
October 2024
Institute of Cardiovascular Research and Sports Medicine, Molecular and Cellular Sports Medicine, German Sport University Cologne, 50933 Cologne, Germany.
(1) Background: Long-term health effects after SARS-CoV-2 infections can manifest in a plethora of symptoms, significantly impacting the quality of life of affected individuals. (2) Aim: The present paper aimed to assess the effects of an individualized and controlled exercise intervention on fatigue and exercise capacity among Long-COVID (LC) patients in an ambulatory setting. (3) Methods: Forty-one (n = 41) LC patients performed an exercise protocol with an individualized control of the patients' training intensity during the study period based on the individual's ability to achieve the target criteria.
View Article and Find Full Text PDFInt J Cardiol
January 2025
Eskisehir Osmangazi University, Faculty of Medicine, Department of Cardiology, Eskisehir, Turkey. Electronic address:
Background: The one-minute sit-to-stand test (1STST) is an easy-to-administer, space and time-saving test for determining functional exercise capacity in cardiac disease. This study aimed to investigate the 1STST -test-retest reliability and convergent validity and compare its physiological responses to the six-minute walk test (6MWT) in patients with Atrial fibrillation (AF).
Methods: Forty-five patients with AF were included in this study.
Chron Respir Dis
October 2024
Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium.
Chronic obstructive pulmonary disease (COPD) is associated with a reduced exercise capacity. Although several field tests for exercise capacity have been modified for non-standard settings, i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!