A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of ultrasound and caliper measurements of normal and inflamed skin thickness. | LitMetric

We have compared ultrasound and Harpenden calipers for the measurement of thickness of non-inflamed and anthralin-inflamed skin. In non-inflamed skin ultrasound gave consistently and significantly lower values (0.87 mm +/- 2.3% s.e.) than calipers (1.1 mm +/- 2.7% s.e.) and the ultrasound/caliper ratio was 0.89 +/- 1.3%. In anthralin-inflamed skin the ultrasound/caliper ratio was not significantly different from unity (1.02 +/- 1.3%), but ultrasound was unable to measure inflamed skin thickness in 18% of cases because the echo could not detect the dermis-subcutaneous fat interface. The proportion of unreadable ultrasound results increased linearly with increase in skin thickness and the variance of ultrasound readings increased as inflammatory skin thickness increased; by contrast caliper variance remained constant. Harpenden calipers cannot be used in all subjects or in skin sites in which skin folds cannot be raised, but if the patient and site to be studied can be selected, Harpenden calipers have a greater precision, reproducibility and reliability than ultrasound for measurement of the thickness of inflamed skin.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2133.1985.tb00083.xDOI Listing

Publication Analysis

Top Keywords

skin thickness
16
inflamed skin
12
harpenden calipers
12
skin
10
measurement thickness
8
anthralin-inflamed skin
8
ultrasound/caliper ratio
8
+/- 13%
8
thickness
6
ultrasound
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!