Purpose: Aseptic loosening often requires major, expensive and invasive revision surgery. Current diagnostic modalities merely show indirect signs of loosening. A recent proof of concept study proposed a non-invasive technique for the quantitative and visual assessment of implant movement as a diagnostic aid for tibial component loosening. The primary research question addressed is whether this novel diagnostic modality can safely and effectively aid the diagnosis of aseptic loosening.
Methods: This clinical study included patients suspected of aseptic total knee arthroplasty (TKA) loosening listed for revision surgery and asymptomatic patients. Safety was evaluated using a numerical rating scale (NRS) for discomfort and by registration of adverse events. Feasibility was assessed by recording the duration and ease of the procedure. Intra- and interrater reliability were evaluated. In symptomatic patients, diagnostic accuracy metrics were evaluated with intra-operative assessment as a reference test.
Results: In total, 34 symptomatic and 38 asymptomatic knees with a TKA were analysed. The median NRS for discomfort during loading was 6 (interquartile range [IQR]: 3.75-7.00) in symptomatic patients and 2 (IQR: 1.00-3.00) in asymptomatic patients. No adverse events were reported. The majority of users found the use of the loading device easy. The median time spent in the computed tomography room was 9 min (IQR: 8.00-11.00). Excellent to good intra- and interrater reliabilities were achieved. Diagnostic accuracy analysis resulted in a sensitivity of 0.91 (95% confidence interval [CI]: 0.72-0.97) and a specificity of 0.72 (95% CI: 0.43-0.90).
Conclusions: The proposed diagnostic method is safe, feasible, reliable and accurate in aiding the diagnosis of aseptic tibial component loosening.
Level Of Evidence: Level II.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ksa.12299 | DOI Listing |
Arch Orthop Trauma Surg
December 2024
Sezione di Chirurgia Protesica ad Indirizzo Robotico Unità di Traumatologia dello Sport, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.
Purpose: Unicompartmental knee arthroplasty (UKA) is a viable option for localized osteoarthritis (OA) or avascular osteonecrosis with several advantages over total knee arthroplasty (TKA). UKA implants may feature a tibial component either all-polyethylene (AP) or metal-backed (MB). This study aims to retrospectively compare the clinical outcomes and survivorship of 74 UKAs over 16 years, focusing on comparing the results and survivorship of MB versus AP tibial tray.
View Article and Find Full Text PDFJBJS Essent Surg Tech
December 2024
Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio.
Background: Unicompartmental knee arthroplasty (UKA) procedures have become much more common in the United States in recent years, with >40,000 UKAs performed annually. However, it is estimated that 10% to 40% of UKAs fail and thus require conversion to total knee arthroplasty (TKA). In the field of total joint arthroplasty, robotic-assisted surgeries have demonstrated advantages such as better accuracy and precision of implant positioning and improved restoration of a neutral mechanical axis.
View Article and Find Full Text PDFJ Orthop Surg Res
December 2024
Department of Orthopedics, The First Affiliated Hospital, China Medical University, Shenyang, 110000, China.
Aim: To evaluate the clinical efficacy and imaging outcomes of a domestically produced orthopedic surgical robot for total knee arthroplasty and to explore its applicability in patients with varying degrees of deformity.
Methods: This study retrospectively included 120 patients who underwent TKA at our hospital between February 2023 and June 2024. The patients were divided into a control group (conventional TKA surgery) and an observation group (robot-assisted TKA surgery), with 60 patients in each group.
Vopr Kurortol Fizioter Lech Fiz Kult
December 2024
National Medical Research Center for Rehabilitation and Balneology, Moscow, Russia.
Unlabelled: Lymphedema is a chronic disabling disease that affects 250 million people worldwide. To this date, it has been proven that treatment of this category of patients should be truly integrated - combining surgical, therapeutic methods and recovery procedures.
Objective: To study the influence of intermittent pneumatic compression (IPC) on microvasculature in patients with lymphedema of the lower extremities.
Arthroplast Today
December 2024
Department of Orthopedic Surgery, Vanderbilt University, Nashville, TN, USA.
Background: Aseptic loosening is the most common aseptic failure modality following total knee arthroplasty. Recent literature suggests that the implant-cement interface is the "weak-link" in fixation and lipid contamination may drive this debonding pattern. Therefore, the purpose of this study was to determine if the "double-butter" technique would significantly decrease lipid contamination of the tibial tray.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!