Background: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry.

Aim: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves.

Methods: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation.

Results: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001).

Conclusion: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.31091DOI Listing

Publication Analysis

Top Keywords

stent expansion
20
relative stent
16
expansion ≥90%
12
stent
10
bicuspid valves
8
stent area
8
area nominal
8
area stent
8
stent ellipticity
8
area
6

Similar Publications

Coronary calcification is a major factor leading to stent under-expansion, and subsequent adverse events. This meta-analysis aimed to evaluate the short and long‑term outcomes of rotational atherectomy (RA), followed by modified balloon (cutting or scoring) (MB) versus plain balloon before drug‑eluting stent implantation for calcified coronary lesions. We searched PubMed, Web of Science (WOS), Scopus, and the Cochrane Library Central Register of Controlled Trials (CENTRAL), from inception until 30 January 2024.

View Article and Find Full Text PDF

New treatments for glaucoma.

Curr Opin Ophthalmol

January 2025

New York Eye Surgery Center, New York City, New York, USA.

Purpose Of Review: This review highlights new Federal Drug Administration (FDA) approved glaucoma treatments to familiarize providers with immediately available options.

Recent Findings: New FDA-approved treatments include the bimatoprost implant, travoprost implant, direct selective laser trabeculoplasty (DSLT), and ocular pressure adjusting pump. The bimatoprost implant is approved for a single administration with effects lasting for about 1 year, as opposed to the nearly 3-year effect for the travoprost implant.

View Article and Find Full Text PDF

Background And Aim: In this retrospective single center cohort study, we report the surgical outcomes of nephron-sparing surgery (NSS) for Wilms' tumor (WT) patients since centralization of pediatric oncology care in the Netherlands, and implementation of technological advancements. Therewith we describe the influence of experience and innovations for this type of surgery.

Methods: We retrospectively assessed all NSS procedures from January 1st 2015 until January 1st 2024 for patients who underwent surgery for a renal tumor at the Princess Máxima Center for Pediatric Oncology.

View Article and Find Full Text PDF
Article Synopsis
  • Heavily calcified coronary artery disease complicates percutaneous coronary intervention (PCI), requiring advanced techniques like cutting balloons (CB), which need standardization for better effectiveness.
  • The study presents the RODIN-CUT technique, which involves sequential CB inflations guided by intravascular ultrasound (IVUS) to improve plaque modification and stent expansion in difficult cases.
  • Results indicate that RODIN-CUT achieved high procedural success rates and minimal complications, suggesting it could be a simple and cost-effective method for treating calcified lesions, though larger studies are needed to confirm its validity.
View Article and Find Full Text PDF

Introduction: In-stent restenosis remains a significant challenge in coronary artery interventions. This study aims to explore the relationship between exercise intensity and stent design, focusing on the coupled response of the stent structure and hemodynamics at different exercise intensities.

Methods: A coupled balloon-stent-plaque-artery model and a fluid domain model reflecting structural deformation were developed to investigate the interaction between coronary stents and stenotic vessels, as well as their impact on hemodynamics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!