Rapid and reliable quantification of urinary malondialdehyde by HILIC-MS/MS: A derivatization-free breakthrough approach.

Anal Chim Acta

Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain.

Published: July 2024

Background: The development of fast analytical methods is crucial for the research, discovery, and confirmation of crucial biomarkers. Furthermore, the implementation of fast analytical strategies contributes to efficient and time-effective procedures. In this sense, analysis of malondialdehyde (MDA) has become an important tool for understanding the role of oxidative stress in various diseases and for evaluating the efficacy of therapeutic interventions.

Results: A rapid and robust liquid chromatography tandem mass spectrometry method (HPLC-MS/MS) has been developed to determine endogenous amounts of malondialdehyde (MDA) in human urine without any associated derivatization reaction. MDA was separated in 4 min through a Urea-HILIC column and was analyzed using a triple quadrupole mass spectrometer in negative electrospray ionization mode. With a 50-fold dilution as the only sample pretreatment after alkaline hydrolysis, no matrix effect was present, which allowed for a fast and simple quantification by means of an external standard calibration with a limit of detection of 0.20 ng mL. The whole methodology was validated by analyzing unspiked and spiked urine samples from ten healthy individuals and comparing with the results obtained by the standard addition method. MDA was detected in all cases, with natural concentrations varying from 0.11 ± 0.03 to 0.31 ± 0.03 mg g creatinine. Accuracies were found to be satisfactory, ranging from 95 % to 101 %. The proposed method also exhibited good repeatability and reproducibility (RSD<15 %) for four quality control levels.

Significance: The main significance of this method is the avoidance of a derivatization reaction for the determination of urinary MDA, this constituting a step forward when compared with previous literature. This breakthrough not only streamlines time analysis to less than 5 min per sample but also results in a more robust procedure. Consequently, the method here developed could be applied to subsequent future research involving the determination of MDA as a lipid peroxidation biomarker, where simple, rapid, and reliable methods could represent a significant improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2024.342737DOI Listing

Publication Analysis

Top Keywords

fast analytical
8
malondialdehyde mda
8
rapid reliable
4
reliable quantification
4
quantification urinary
4
urinary malondialdehyde
4
malondialdehyde hilic-ms/ms
4
hilic-ms/ms derivatization-free
4
derivatization-free breakthrough
4
breakthrough approach
4

Similar Publications

In this work we analytically investigate the alignment mechanism of self-propelled ellipse-shaped cells in two spatial dimensions interacting via overlap avoidance. By considering a two-cell system and imposing certain symmetries, we obtain an analytically tractable dynamical system, which we mathematically analyse in detail. We find that for elongated cells there is a half-stable steady state corresponding to perfect alignment between the cells.

View Article and Find Full Text PDF

kMetaShot: a fast and reliable taxonomy classifier for metagenome-assembled genomes.

Brief Bioinform

November 2024

Department of Biosciences, Biotechnology and Environment, University of Bari Aldo Moro, Via E. Orabona 4, 70126, Bari, Italy.

The advent of high-throughput sequencing (HTS) technologies unlocked the complexity of the microbial world through the development of metagenomics, which now provides an unprecedented and comprehensive overview of its taxonomic and functional contribution in a huge variety of macro- and micro-ecosystems. In particular, shotgun metagenomics allows the reconstruction of microbial genomes, through the assembly of reads into MAGs (metagenome-assembled genomes). In fact, MAGs represent an information-rich proxy for inferring the taxonomic composition and the functional contribution of microbiomes, even if the relevant analytical approaches are not trivial and still improvable.

View Article and Find Full Text PDF

Timely identification of highly pathogenic bacteria is crucial for efficient mitigation of the connected harmful health effects. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) of intact cells enables fast identification of the microorganisms based on their mass spectrometry protein fingerprint profiles. However, the MALDI-TOF MS examination must be preceded by a time-demanding cultivation of the native bacteria to isolate representative cell samples to obtain indicative fingerprints.

View Article and Find Full Text PDF

Although various sensors specifically developed for target analytes are available, affordable biosensing solutions with broad applicability are limited. In this study, a cost-effective biosensor for detecting human epidermal growth factor receptor 2 (HER2) was developed using custom-made gold leaf electrodes (GLEs). A novel strategy for antibody immobilization on a gold surface, for the first time mediated by protein L and HER2-specific antibody trastuzumab, was examined using commercial screen-printed gold electrodes and GLEs.

View Article and Find Full Text PDF

Efficient control strategy for electric furnace temperature regulation using quadratic interpolation optimization.

Sci Rep

January 2025

Department of Theoretical Electrical Engineering and Diagnostics of Electrical Equipment, Institute of Electrodynamics, National Academy of Sciences of Ukraine, Beresteyskiy, 56, Kyiv-57, Kyiv, 03680, Ukraine.

Electric furnaces play an important role in many industrial processes where precise temperature control is essential to ensure production efficiency and product quality. Traditional proportional-integral-derivative (PID) controllers and their modified versions are commonly used to maintain temperature stability by reacting quickly to deviations. In this study, the real PID plus second-order derivative (RPIDD) controller is introduced for the first time for industrial temperature control applications, which is a novel alternative that has not yet been investigated in the literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!