Importance: Adequate situational awareness in patient care increases patient safety and quality of care. To improve situational awareness, an innovative, low-fidelity simulation method referred to as Room of Improvement, has proven effective in various clinical settings.

Objective: To investigate the impact after 3 months of Room of Improvement training on the ability to detect patient safety hazards during an intensive care unit shift handover, based on critical incident reporting system (CIRS) cases reported in the same hospital.

Methods: In this educational intervention, 130 healthcare professionals observed safety hazards in a Room of Improvement in a 2 (time 1 vs time 2)×2 (alone vs in a team) factorial design. The hazards were divided into immediately critical and non-critical.

Results: The results of 130 participants were included in the analysis. At time 1, no statistically significant differences were found between individuals and teams, either overall or for non-critical errors. At time 2, there was an increase in the detection rate of all implemented errors for teams compared with time 1, but not for individuals. The detection rate for critical errors was higher than for non-critical errors at both time points, with individual and group results at time 2 not significantly different from those at time 1. An increase in the perception of safety culture was found in the pre-post test for the questions whether the handling of errors is open and professional and whether errors are discussed in the team.

Discussion: Our results indicate a sustained learning effect after 12 weeks, with collaboration in teams leading to a significantly better outcome. The training improved the actual error detection rates, and participants reported improved handling and discussion of errors in their daily work. This indicates a subjectively improved safety culture among healthcare workers as a result of the situational awareness training in the Room of Improvement. As this method promotes a culture of safety, it is a promising tool for a well-functioning CIRS that closes the loop.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11138267PMC
http://dx.doi.org/10.1136/bmjoq-2023-002608DOI Listing

Publication Analysis

Top Keywords

room improvement
20
patient safety
12
situational awareness
12
low-fidelity simulation
8
cirs cases
8
safety hazards
8
time
8
time time
8
non-critical errors
8
errors time
8