Background: The Wagner Cone Prosthesis was designed to address complex femoral deformities during total hip arthroplasty (THA), but its mid-term component survivorship and functional outcomes remain undetermined. The objectives of this study were to determine the implant survivorship, patient satisfaction, functional outcomes, osseointegration as seen radiographically, implant subsidence, and complications of THA using the Wagner Cone Prosthesis stem at intermediate-term follow-up.

Methods: This study involved 302 patients with proximal femoral deformities, including developmental hip dysplasia and Legg-Calvé-Perthes disease, who underwent a total of 320 primary THAs using the Wagner Cone Prosthesis. The average age at the time of surgery was 49.4 ± 14.5 years (range, 18.8 to 85.6 years). Patient satisfaction was recorded using a self-administered questionnaire assessing satisfaction in 4 domains. The University of California at Los Angeles (UCLA) activity score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Oxford Hip Score (OHS), the Forgotten Joint Score (FJS), radiographic outcomes, and complications were recorded. The mean follow-up time was 10.1 years (range, 5.2 to 15.5 years).

Results: Survivorship of the Wagner Cone Prosthesis was 98.7% (95% confidence interval [CI]: 97.2% to 100%) with stem revision as the end point and 95.8% (95% CI: 93.5% to 98.2%) with reoperation for any reason as the end point at 10 years postoperatively. In total, 3 stems were revised: 2 for infection and 1 for chronic hip dislocation. The median patient satisfaction score was 95 (interquartile range [IQR], 80 to 100), median UCLA score was 6 (IQR, 6 to 7), median WOMAC score was 18 (IQR, 16 to 22), median OHS was 40 (IQR, 36 to 47), and median FJS was 80 (IQR, 76 to 88) at the time of final follow-up. All Wagner Cone stems that were not revised showed radiographic evidence of osseointegration, with a mean stem subsidence of 0.9 ± 0.8 mm at the most recent follow-up.

Conclusions: The use of the Wagner Cone Prosthesis stem in patients with complex femoral anatomy undergoing primary THA is associated with excellent component survivorship, high levels of patient satisfaction, good functional outcomes, and reliable osseointegration with minimal stem subsidence as seen on radiographs at intermediate-term follow-up.

Level Of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.23.00849DOI Listing

Publication Analysis

Top Keywords

wagner cone
28
cone prosthesis
20
patient satisfaction
16
functional outcomes
12
iqr median
12
femoral anatomy
8
total hip
8
hip arthroplasty
8
complex femoral
8
femoral deformities
8

Similar Publications

[Navigated and minimally invasive screw osteosynthesis of a talus fracture].

Unfallchirurgie (Heidelb)

December 2024

Klinik für Unfallchirurgie, Technische Universität München, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, München, Deutschland.

Objective Of Surgery: The aim of this surgery is to safeguard the multifragmentary and nondisplaced talus fracture (body and neck) against secondary dislocation in a navigated and minimally invasive manner using screw osteosynthesis.

Indications: Due to the young age of the patient in the presented case and the risk of a possible secondary dislocation, the decision was made in favor of surgical treatment.

Contraindications: Soft tissue swelling, wound infections and allergies to the osteosynthesis material.

View Article and Find Full Text PDF

Purpose: To evaluate the response of the ureter and renal pelvis to direct targeting by histotripsy guided by cone-beam CT (CBCT) in a human-scale porcine chronic-survival model.

Methods: Bilateral ureteral histotripsy treatments were completed on 6 female swine (n=12). Animals were divided into two groups: Acute (n=2 animals, 4 treatments, sacrificed at Day 0) and Chronic (n=4 animals, 8 treatments, sacrificed at Day 7 (n=2) and Day 28 (n=2)).

View Article and Find Full Text PDF

Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.

Strahlenther Onkol

December 2024

Klinik für Strahlentherapie und Radioonkologie, Klinikum Stuttgart, Stuttgart, Germany.

Objective: The precise daily positioning of patients during radiation therapy determines the quality of the entire treatment. To avoid additional radiation exposure from regular cone-beam CT (CBCT) scans, surface-guided radiotherapy systems (SGRT) are increasingly used. The aim of this prospective clinical study was to evaluate the advantages, feasibility, and pitfalls of SGRT using the surface tracking recorder prototype of the camera component of ExacTrac Dynamic (Brainlab AG, Munich, Germany).

View Article and Find Full Text PDF

Purpose: Conventional image-guided radiotherapy (IGRT) of the prostate bed is challenged by the varying anatomy due to dynamic changes of surrounding organs such as the bladder and rectum. This leads to changed dose coverage of target and surrounding tissue. The novel online adaptive radiotherapy (oART) aims to improve target coverage as well as reduce dose exposure to surrounding healthy tissues by daily reoptimization of treatment plans.

View Article and Find Full Text PDF

Single-Taper Conical Tapered Stem in Total Hip Arthroplasty for Primary Osteoarthritis: A Comparative Long-Term Registry Evaluation.

J Clin Med

October 2024

SC Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, via Pupilli 1, 40136 Bologna, Italy.

Article Synopsis
  • Single-taper conical tapered stems (STCTSs) are evaluated for their effectiveness in total hip arthroplasty (THA) for primary osteoarthritis, comparing their outcomes with other cementless stems.
  • The study analyzed data from 1,773 STCTS cases against 37,944 cementless stem cases, showing that both cohorts had similar long-term survival rates, but STCTSs performed slightly better in terms of revision rates and survival for women under 65.
  • Overall, STCTSs showed reliable long-term results, establishing them as a viable option for femoral reconstruction in THA that is comparable to other cementless stem designs.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!