Temporal asynchrony is a cue for the perceptual segregation of spatial regions. Past research found attribute invariance of this phenomenon such that asynchrony induces perceptual segmentation regardless of the changing attribute type, and it does so even when asynchrony occurs between different attributes. To test the generality of this finding and obtain insights into the underlying computational mechanism, we compared the segmentation performance for changes in luminance, color, motion direction, and their combinations. Our task was to detect the target quadrant in which a periodic alternation in attribute was phase-delayed compared to the remaining quadrants. When stimulus elements made a square-wave attribute change, target detection was not clearly attribute invariant, being more difficult for motion direction change than for luminance or color changes and nearly impossible for the combination of motion direction and luminance or color. We suspect that waveform mismatch might cause anomalous behavior of motion direction since a square-wave change in motion direction is a triangular-wave change in the spatial phase (i.e., a second-order change in the direction of the spatial phase change). In agreement with this idea, we found that the segregation performance was strongly affected by the waveform type (square wave, triangular wave, or their combination), and when this factor was controlled, the performance was nearly, though not perfectly, invariant against attribute type. The results were discussed with a model in which different visual attributes share a common asynchrony-based segmentation mechanism.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146091 | PMC |
http://dx.doi.org/10.1167/jov.24.5.15 | DOI Listing |
Sensors (Basel)
December 2024
Institute of Communications Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.
A core dielectric cylindrical rod wrapped in a dielectric circular pipe whose outer surface is enclosed by a helical conducting strip grating that is skewed along the axial direction is herein analyzed using the asymptotic strip boundary conditions along with classical vector potential analysis. Targeted for use as a cylindrical holographic antenna, the resultant field solutions facilitate the aperture integration of the equivalent cylindrical surface currents to obtain the radiated far fields. As each rod section of a certain skew angle exhibits a distinct modal attribute; this topology allows for the distribution of the cylindrical surface impedance via the effective refractive index to be modulated, as in gradient-index (GRIN) materials.
View Article and Find Full Text PDFSensors (Basel)
December 2024
School of Sport and Physical Activity, College of Health, Wellbeing and Life Sciences, Sheffield Hallam University, Sheffield S10 2BP, UK.
RaceRunning is a sport for disabled people and successful performance depends on reducing the amount of time spent travelling a specific distance. Performance analysis in RaceRunning athletes is based on traditional methods such as recording race time, distances travelled and frequency (sets and reps) that are not sufficient for monitoring training loads. The aims of this study were to monitor training loads in typical training sessions and evaluate technical adaptations in RaceRunning performance by acquiring sensor metrics.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
InnoVital Systems Inc., Calverton, MD 20705, USA.
This study examines the three-axis vibration isolation capabilities of a full-scale magnetorheological (MR) seat suspension system utilizing experimental methods to assess performance under both single-axis and simultaneous three-axis input conditions. To achieve this, a semi-active MR seat damper was designed and manufactured to address excitations in all three axes. The damper effectiveness was tested experimentally for axial and lateral motions, focusing on dynamic stiffness and loss factor using an MTS machine.
View Article and Find Full Text PDFBrain Sci
November 2024
Physiotherapy Department, School of Health & Care Sciences, University of West Attica (UNIWA), 12243 Athens, Greece.
Background/objectives: Patients with non-specific chronic neck pain (NSCNP) exhibit sensorimotor disturbances, with proprioception impairment considered an important aspect. The aim of this study was to assess the reliability and validity of a novel inertial sensor-based electrogoniometer (KFORCE Sens) for cervical spine (CS) proprioception measurement in patients with NSCNP.
Methods: The within-day intra-rater reliability of CS proprioception and its association with patient demographics and clinical status were examined in fifty-nine patients with NSCNP, aged between 25-65 years, recruited from primary care.
Cancers (Basel)
December 2024
Radiation Oncology Department, Centre Frederic Joliot, 76000 Rouen, France.
Background/objectives: An on-board imager on a linear accelerator allows the acquisition of kV-2D images during irradiation. Overlaying specific structures on these images enables the visual verification of movement at regular frequencies. Our aim was to validate this tracking method for the stereotactic treatment of bone metastases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!