Background: Critical care nurses should help in reducing noise to improve the well-being of patients and health care providers.

Aim/s: To measure actual noise levels in intensive care units, identify nurses' perceived irritation levels of noise sources and examine the impact of noise on nurses' work performance and well-being.

Study Design: This cross-sectional study was conducted from January to April 2023 at a teaching hospital's six intensive care units. It involved three phases: mapping locations for noise measurement, actual noise measurements in decibels and a cross-sectional survey to identify nurses' perceptions and the adverse effects of noise. Actual noise was measured between patients' beds, nursing stations and beside 16 noise sources for 7 days 24 h a day. For nurse perceptions, the mean of perceived irritation levels by a Likert scale for each noise source was calculated to present perceived noise levels. Ranking of noise sources according to the actual measured and perceived irritation by nurses was done based on mean values. Curve estimation regression test was used to predict the relationship between actual and perceived noise and stepwise multiple linear regression identified factors associated with noise adverse effects.

Results: The mean noise level in the intensive care units was 65.55 dB. Nurses perceived mechanical ventilator alarms as the most irritating noise. However, the mean noise measurements showed that conversations among colleagues were the primary source of noise. There was no significant predictive relationship between the actual and perceived noise. Nurses reported feeling distressed, irritable, fatigued and less productive due to noise.

Conclusions: There was a discrepancy between actual and perceived noise levels by nurses. Perceived noise levels had more impact on nurses than actual noise.

Relevance To Clinical Practice: By incorporating both objective measurements and subjective perceptions into efforts aimed at reducing noise, health care providers can create quieter intensive care units.

Download full-text PDF

Source
http://dx.doi.org/10.1111/nicc.13095DOI Listing

Publication Analysis

Top Keywords

perceived noise
24
noise
23
noise levels
20
intensive care
16
care units
16
actual noise
12
perceived irritation
12
noise sources
12
actual perceived
12
perceived
10

Similar Publications

Individual differences elucidate the perceptual benefits associated with robust temporal fine-structure processing.

Proc Natl Acad Sci U S A

January 2025

Department of Communication Science and Disorders, University of Pittsburgh, Pittsburgh, PA 15213.

The auditory system is unique among sensory systems in its ability to phase lock to and precisely follow very fast cycle-by-cycle fluctuations in the phase of sound-driven cochlear vibrations. Yet, the perceptual role of this temporal fine structure (TFS) code is debated. This fundamental gap is attributable to our inability to experimentally manipulate TFS cues without altering other perceptually relevant cues.

View Article and Find Full Text PDF

Latent fingerprints (LFPs) are invisible impressions that need to be developed before being used for criminal investigation; however, existing fingerprint visualization techniques face challenges, such as complex preparation and poor contrast. To advance practical fingerprint detection, green-emissive micron-sized curcumin/kaolin composites were synthesized a facile and cost-effective one-step physical cross-linking method, which exhibited unprecedented performance in developing diversified marks, including LFPs, knuckle prints, palm prints, and footprints, with clear three-level details on various substrates. Notably, the powders successfully developed LFPs that were aged for 30 days and even up to 100 days, meeting the stringent requirements for comprehensive forensic application.

View Article and Find Full Text PDF

Clinical Manifestations.

Alzheimers Dement

December 2024

Newcastle University, Newcastle upon Tyne, United Kingdom.

Background: Hearing loss is associated with cognitive and neuroimaging markers of Alzheimer's disease dementia but it is unclear how specific measures relate to these after accounting for a range of hearing abilities.

Method: 200 participants (155 cognitively normal, 25 mild cognitively impaired and 20 Alzheimer's disease dementia) underwent auditory testing (peripheral and central abilities), cognitive testing and MR scanning (structural and diffusion-weighted sequences) to evaluate the relationship between hearing, cognition and imaging brain measures.

Result: Central auditory measures such as speech-in-noise perception and auditory memory for longer durations were associated with cognitive impairment across the Alzheimer's disease continuum and specific auditory measures were independently associated with morphometric and diffusion-weighted brain measures.

View Article and Find Full Text PDF

Remote epitaxy and exfoliation of vanadium dioxide via sub-nanometer thick amorphous interlayer.

Nat Commun

January 2025

Department of Materials Science & International Institute of Intelligent Nanorobots and Nanosystems, State Key Laboratory of Surface Physics, Fudan University, Shanghai, 200438, People's Republic of China.

The recently emerged remote epitaxy technique, utilizing 2D materials (mostly graphene) as interlayers between the epilayer and the substrate, enables the exfoliation of crystalline nanomembranes from the substrate, expanding the range of potential device applications. However, remote epitaxy has been so far applied to a limited range of material systems, owing to the need of stringent growth conditions to avoid graphene damaging, and has therefore remained challenging for the synthesis of oxide nanomembranes. Here, we demonstrate the remote epitaxial growth of an oxide nanomembrane (vanadium dioxide, VO) with a sub-nanometer thick amorphous interlayer, which can withstand potential sputtering-induced damage and oxidation.

View Article and Find Full Text PDF

An adaptive protocol to assess physiological responses as a function of task demand in speech-in-noise testing.

J Neurosci Methods

December 2024

Politecnico di Milano, Piazza Leonardo da Vinci, 32, Milan, 20133, Italy. Electronic address:

Background: Acoustic challenges impose demands on cognitive resources, known as listening effort (LE), which can substantially influence speech perception and communication. Standardized assessment protocols for monitoring LE are lacking, hindering the development of adaptive hearing assistive technology.

New Method: We employed an adaptive protocol, including a speech-in-noise test and personalized definition of task demand, to assess LE and its physiological correlates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!