Preoperative diagnosis of adhesion severity between the abdominal wall and intestinal tract with novel abdominal ultrasound methodology to enhance surgical safety.

Surgery

Department of Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan; Department of Hepato-Biliary-Pancreatic Surgery, Hyogo Medical University, Nishinomiya, Japan. Electronic address:

Published: August 2024

Background: Adhesions between the abdominal wall and intestinal tract from previous surgeries can complicate reoperations; however, predicting the extent of adhesions preoperatively is difficult. This study aimed to develop a straightforward approach for predicting adhesion severity using a novel abdominal ultrasound technique that quantifies the displacement of motion vectors of two organs to enhance surgical safety. The efficacy of this methodology was assessed experimentally and clinically.

Methods: Using Aplio500T, a system we developed, we measured the displacement of the upper peritoneum and intestinal tract as a vector difference and computed the motion difference ratio. Twenty-five rats were randomized into surgery and nonsurgery groups. The motion difference ratio was assessed 7 days after laparotomy to classify adhesions. In a clinical trial, 51 patients undergoing hepatobiliary pancreatic surgery were evaluated for the motion difference ratio within 3 days preoperatively. Intraoperatively, adhesion severity was rated and compared with the motion difference ratio. A receiver operating characteristic curve was used to appraise the diagnostic value of the motion difference ratio.

Results: In the animal experiment, the adhesion group exhibited a significantly higher motion difference ratio than the no-adhesion group (0.006 ± 0.141 vs 0.435 ± 0.220, P < .001). In the clinical trial, the no-adhesion or no-laparotomy group had a motion difference ratio of 0.128 ± 0.074; mild-adhesion group, 0.143 ± 0.170; moderate-adhesion group, 0.326 ± 0.153; and high-adhesion group, 0.427 ± 0.152. The motion difference ratio receiver operating characteristic curve to diagnose the adhesion level (≥moderate) was 0.938, indicating its high diagnostic value (cut-off 0.204).

Conclusion: This methodology may preoperatively predict moderate-to-high adhesions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.surg.2024.04.020DOI Listing

Publication Analysis

Top Keywords

motion difference
32
difference ratio
28
adhesion severity
12
intestinal tract
12
motion
9
difference
9
abdominal wall
8
wall intestinal
8
novel abdominal
8
abdominal ultrasound
8

Similar Publications

The preservation of the original configurations of root canals during endodontic preparation is crucial for treatment success. Nickel-titanium (NiTi) rotary systems have been refined to optimize canal shaping while minimizing iatrogenic errors. This study aimed to evaluate and compare the shaping efficacy of the novel R-Motion (RM) and the established WaveOne Gold (WG) systems using micro-computed tomography (micro-CT).

View Article and Find Full Text PDF

Background: Respiratory motion during radiotherapy (RT) may reduce the therapeutic effect and increase the dose received by organs at risk. This can be addressed by real-time tracking, where respiration motion prediction is currently required to compensate for system latency in RT systems. Notably, for the prediction of future images in image-guided adaptive RT systems, the use of deep learning has been considered.

View Article and Find Full Text PDF

Two-dimensional identification of lower limb gait features based on the variational modal decomposition of sEMG signal and convolutional neural network.

Gait Posture

December 2024

Engineering Research Center of the Ministry of Education for Intelligent Rehabilitation Equipment and Detection Technologies, Hebei University of Technology, Tianjin 300401, PR China; Hebei Key Laboratory of Robot Sensing and Human-robot Interaction, Hebei University of Technology, Tianjin 300401, PR China; School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, PR China. Electronic address:

Background: Gait feature recognition is crucial to improve the efficiency and coordination of exoskeleton assistance. The recognition methods based on surface electromyographic (sEMG) signals are popular. However, the recognition accuracy of these methods is poor due to ignoring the correlation of the time series of sEMG signals.

View Article and Find Full Text PDF

Objective: ADHD is one of the most common neurodevelopmental disorders, seen in children and adolescents, and is often treated with various pharmacological agents, especially methylphenidate. There are differing opinions in the literature regarding the cardiovascular safety of long-term methylphenidate use. Studies suggest that the drug may increase the risk of hypertension, myocardial infarction, ventricular arrhythmia, sudden cardiac death, cardiomyopathy, heart failure (HF), pulmonary hypertension, and stroke.

View Article and Find Full Text PDF

Through the mobilization of movable objects due to the extreme hydraulic conditions during a flood event, blockages, damage to infrastructure, and endangerment of human lives can occur. To identify potential hazards from aerial imagery and take appropriate precautions, a change detection tool (CDT) was developed and tested using a study area along the Aisch River in Germany. The focus of the CDT development was on near real-time analysis of point cloud data generated by structure from motion from aerial images of temporally separated surveys, enabling rapid and targeted implementation of measures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!