Comparison between Zone 2 and Zone 3 distal anastomoses for aortic arch replacement in terms of invasiveness.

Gen Thorac Cardiovasc Surg

Department of Cardiovascular Surgery, Nerima Hikarigaoka Hospital, 2-11-1 Hikarigaoka, Nerima-Ku, Tokyo, 179-0075, Japan.

Published: January 2025

AI Article Synopsis

  • * Results indicated that Zone 2 anastomosis had significantly lower rates of new-onset recurrent laryngeal nerve palsy (1.4% vs. 25.0%) and shorter lower body perfusion arrest times compared to Zone 3 anastomosis.
  • * The research concludes that using a frozen elephant trunk or stent-graft for Zone 2 procedures could reduce complications and improve safety, although patient age was the only independent predictor of overall

Article Abstract

Objectives: Zone 2 anastomosis with total cervical branch reconstruction for acute type A aortic dissection and aortic arch aneurysms became possible after stent-graft introduction. This may be an easier procedure and reduce the risk of recurrent laryngeal nerve palsy. Therefore, this study aimed to compare the outcomes between Zone 2 and Zone 3 distal anastomoses.

Methods: After evaluating the patient data in our institute between April 2016 and April 2022, the patients in whom distal anastomosis was performed at Zone 2 with a stent-graft were defined as the Zone 2 group (n = 70). The patients in whom distal anastomosis was performed at Zone 3 were defined as the Zone 3 group (n = 24).

Results: The incidence of new-onset recurrent nerve palsy was one patient (1.4%) in the Zone 2 group and six patients (25.0%) in the Zone 3 group (p < 0.001). The lower body perfusion arrest time was 44.3 ± 9.1 min in the Zone 2 group and 52.9 ± 12.8 min in the Zone 3 group (p = 0.005). There were no significant differences in in-hospital mortality and morbidities. Multivariable analysis showed that only age was an independent predictor of overall mortality.

Conclusions: Performing distal anastomosis at Zone 2 with a frozen elephant trunk or stent-graft reduced the lower body perfusion arrest time and possibly prevented recurrent nerve palsy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11748-024-02045-7DOI Listing

Publication Analysis

Top Keywords

zone group
16
zone
10
zone zone
8
zone distal
8
aortic arch
8
nerve palsy
8
patients distal
8
distal anastomosis
8
anastomosis performed
8
performed zone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!