Purpose: This study aimed to assess the feasibility and short-term outcomes of different manufactured proximal and distal stent graft components during fenestrated endovascular aortic repair (FEVAR).

Materials And Methods: A multicenter retrospective review was conducted at 3 aortic centers, involving all consecutive patients who underwent FEVAR utilizing a customized Dacron-based tubular proximal and a distal bifurcated polytetrafluoreten (PTFE)-based commercially available stent grafts. Primary outcomes were 30 day mortality, major adverse events, and technical and clinical success. Secondary outcomes assessed stent graft migration, occurrence of types I/III endoleak, and reintervention.

Results: A total of 23 FEVAR cases across all centers were included in this study. Technical success was achieved in all cases, with a median procedure time of 183 (153-244) minutes. There were no major adverse events, except for 1 transient acute renal failure. The median follow-up period was 23 (17-28) months. All target vessels retained patent with the exception of 1 right renal fenestration that showed signs of kinking at the first follow-up, and despite secondary intervention with relining and distal extension, there was an occlusion afterward and 1 hepatic artery with a separate fenestration. This and 1 successful relining of a superior mesenteric artery kink were the only reinterventions in this cohort. One case of persistent type 1b endoleak was reported in a patient with chronic type B aortic dissection, which resolved with distal extension on the external iliac artery 5 months after the index procedure. No deaths occurred throughout the follow-up with, and there were no signs of stent graft migration or type 3 endoleak.

Conclusion: The use of commercially available PTFE-based bifurcated stent grafts to extend distally the tubular graft appears to be a feasible approach during FEVAR, with promising short-term outcomes. Further studies are necessary to define the applicability of this solution and evaluate long-term outcomes.

Clinical Impact: This multicentric study on fenestrated endovascular aortic repair (FEVAR) demonstrates the feasibility and good short-term outcomes of utilizing a PTFE-based commercially available stent graft to extend the proximal tubular custom-made fenestrated stent graft. The high technical success rate, absence of major adverse events, and low occurrence of complications such as stent graft migration and endoleaks highlight the potential clinical benefits of this approach with an off-the-shelf distal extension whose delivery system does not cross the fenestrations intraoperatively.

Download full-text PDF

Source
http://dx.doi.org/10.1177/15266028241257090DOI Listing

Publication Analysis

Top Keywords

stent graft
24
fenestrated endovascular
12
endovascular aortic
12
aortic repair
12
short-term outcomes
12
major adverse
12
adverse events
12
graft migration
12
distal extension
12
proximal distal
8

Similar Publications

The popliteal artery segment is particularly challenging for endovascular treatment. Stents used for treating popliteal artery lesions are usually associated with an increased risk of stent fracture and re-occlusion. The Supera stent is designed to withstand mechanical stress, with a low risk of fracture.

View Article and Find Full Text PDF

Introduction: The management of urinary tract stones, particularly kidney allograft stones, presents unique challenges for kidney transplant recipients because of their prevalence and specific clinical considerations. Here, we describe a case in which percutaneous nephrolithotomy was successfully used to fragment a large kidney allograft stone ≥20 mm in size.

Case Presentation: A 57-year-old woman who underwent ureteroureterostomy post simultaneous pancreas-kidney transplantation presented with gross hematuria after 15 years.

View Article and Find Full Text PDF

An a (AEF) is a rare but life-threatening condition where an abnormal connection forms between the aorta and the gastrointestinal tract, most commonly the duodenum. It can be primary (arising spontaneously due to an aortic aneurysm or infection) or secondary (complicating prior vascular surgery). Immediate recognition and surgical intervention are critical to manage severe gastrointestinal bleeding and prevent fatal outcomes.

View Article and Find Full Text PDF

In situ Laser Fenestrations of Visceral Endografts (InLoVE) Midterm Outcomes From a Multicentre Study.

Eur J Vasc Endovasc Surg

December 2024

Division of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Department of Clinical Science and Education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden.

Objective: Emergent complex abdominal aortic diseases are challenging to treat. During in situ laser fenestration (ISLF), aortic branches are covered and flow is restored with in situ fenestration of the stent graft, with promising midterm results. This study aimed to expand on the limited body of knowledge of midterm outcomes of ISLF in renovisceral aortic pathology in a multicentre setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!