In this paper, a comprehensive hybrid K-edge/XRF densitometer (HKED) device model is constructed using MCNP simulation. After the modeling process, a systematic simulation study is conducted to analyze the physical parameters and material selection of KED and XRF. The simulation results reveal that the optimal parameters for the X-ray tube are an X-ray source voltage of 160 kV and a 1 mm Fe filter. The sample should be placed in a vial with an inner diameter of 1.4 cm and an outer diameter of 2 cm. For the KED technique, the determined main parameters are a 1.9 cm Fe filter rod and an inner diameter of 0.08 cm for the collimator. For the XRF technique, the determined main parameters are a 0.01 cm Gd filter and an inner diameter of 0.3 cm for the collimator, with a detector angle of 150°. After selecting appropriate parameters, the average calibration factor Δμ of the KED technique was found to be 3.301 cm g, with a relative standard deviation (RSD) of 3.36%. Additionally, the comparison between the simulated and calculated values of uranium concentration revealed a minimum measurement error of 0.4%. The minimum detection concentration of KED for uranium solutions is approximately 1 g/L. For plutonium solutions ranging from 0.5 to 20 g/L, linear fitting of the K net peak area and plutonium concentration showed a coefficient of determination (R) of 0.999. The detection limit of XRF for plutonium measurement was 2.33✕10 g/L. The linear fitting coefficients (R) of uranium concentration versus K-edge transmission rate and plutonium concentration versus K net peak area for the hybrid technique in measuring uranium-plutonium mixed solutions are determined as 0.999 and 0.996, respectively, demonstrating the response relationship of the HKED device to uranium and plutonium under different concentrations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.apradiso.2024.111367 | DOI Listing |
Quant Imaging Med Surg
January 2025
Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany.
Background: With globalization, oculoplastic surgeons must understand the intricate morphological nuances of the periocular region across ethnicities to ensure precise treatment and avoid facial disharmony or dysfunction. Direct comparisons in two-dimensional (2D)-based periocular morphology between studies can be challenging due to the limited number of parameters and complicated variations in equipment, environments, measurement personnel, and methods. Therefore, it is imperative to explore the detailed three-dimensional (3D) periocular morphological disparities between young Caucasian and Chinese populations.
View Article and Find Full Text PDFIntroduction: Cataract surgery has been reported to have a reducing effect on intraocular pressure (IOP) in glaucomatous and non-glaucomatous eyes. This effect seems to be more noticeable in eyes with narrow angles (NAs) than in eyes with open angles (OAs). Decrease in IOP may be a result of the increase in anterior chamber angle (ACA) and Schlemm canal (SC) after cataract surgery.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of BioMechanical Engineering, Bio-Inspired Technology Group, Faculty of Mechanical Engineering, Delft University of Technology, Delft, Netherlands.
Percutaneous pancreatic core biopsy is conclusive but challenging due to large-diameter needles, while smaller-diameter needles used in aspiration methods suffer from buckling and clogging. Inspired by the ovipositor of parasitic wasps, which resists buckling through self-propulsion and prevents clogging via friction-based transport, research has led to the integration of these functionalities into multi-segment needle designs or tissue transport system designs. This study aimed to combine these wasp-inspired functionalities into a single biopsy needle by changing the interconnection of the needle segments.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopedics, Qilu Hospital of Shandong University, Cheeloo College of Medicine, Shandong University, Jinan, 250012, Shandong, PR, China.
Currently, Unilateral biportal endoscopy is widely used in the surgical treatment of lumbar spinal stenosis. To investigate the feasibility of bilateral synchronous UBE to unilateral laminotomy and bilateral decompression(BS-UBE-ULBD) for treating two-level lumbar spinal stenosis (LSS). Sixty-four patients with two-level lumbar spinal stenosis (LSS) treated with BS-UBE-ULBD from October 2022 to January 2024 were retrospectively analyzed.
View Article and Find Full Text PDFTissue Eng Regen Med
January 2025
College of Materials Science and Engineering, Hunan University, Changsha, 410072, People's Republic of China.
Background: Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
Methods: A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!