Exploring morphometric transformations in temperature-sensitive NiTi instruments alongside real-time intracanal temperature dynamics.

Int Endod J

Department of Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates.

Published: September 2024

Aim: This study was twofold: (i) it aimed to investigate the morphometric changes of three temperature-sensitive nickel-titanium (NiTi) instruments at different temperatures, and (ii) to conduct an in vivo real-time analysis of intracanal temperature changes.

Methods: Changes in the shape and length of XP-Endo Shaper, XP-Endo Finisher, and XP-Endo Finisher-R were evaluated in real time whilst heated in a temperature-controlled water bath from 22 to 45°C. Instruments were fixed to a laminated water-resistant 1 mm graph paper attached to a stone block. Instruments were imaged whilst subjected to increasing temperature using a digital camera attached to an operating microscope. From recorded videos, still frames were extracted at 10-s intervals and changes in the length and shape of each instrument were measured and changes were plotted against time. Moreover, the intracanal temperature of distal roots of lower molars was measured in vivo for patients attending the clinic for non-surgical root canal treatments. The temperature was measured using a K-type thermocouple probe inserted into the mid-root level after irrigating the canal with a solution set at room temperature (22°C) or heated to 45°C. The intraoral and intracanal temperatures were recorded using a video camera for 180 s at 5-s intervals to plot the change in the intraoral and intracanal temperature, after both irrigation solution temperatures, with time.

Results: The shape transformation of XP-Endo Shaper began at 31.5 ± 2.0°C and reached its optimal transformation at 35.1 ± 1.0°C. For the Finisher and Finisher-R, shape transformations began at 29.2 ± 1.9 and 26.9 ± 2.2°C reaching the optimal transformation at 33.9 ± 1.4 and 32.7 ± 1.7°C, respectively. The average decreases in lengths of XP-Endo Shaper, Finisher, and Finisher-R after full transformation were 0.43 ± 0.23, 1.07 ± 0.22, and 1.15 ± 0.22 mm, respectively. The intracanal temperature reached 32.9 ± 0.8 and 33.2 ± 1.0°C after 3 min of application of irrigation solutions set at 22 or 45°C, respectively.

Conclusion: The tested instruments exhibited diverse changes in their shapes and lengths at varying temperatures. Despite the temperature of the irrigation solution, the intracanal temperature consistently remained lower than the intracanal temperature once equilibrium was reached. This highlights the importance of considering the temperature of irrigation solution during in vitro testing of endodontic instruments.

Download full-text PDF

Source
http://dx.doi.org/10.1111/iej.14100DOI Listing

Publication Analysis

Top Keywords

intracanal temperature
28
temperature
12
xp-endo shaper
12
temperature irrigation
12
irrigation solution
12
niti instruments
8
intracanal
8
intraoral intracanal
8
optimal transformation
8
finisher finisher-r
8

Similar Publications

Background: This randomized clinical trial aimed to evaluate the effect of intracanal cryotherapy with 2-4 °C normal saline irrigation on post-operative pain after single-visit non-surgical root canal retreatment.

Methods: Forty-six single-rooted, single-canal teeth requiring non-surgical root canal retreatment were randomly assigned to two groups (n = 23): a cryotherapy group and a control group. All the treatments were completed during a single visit.

View Article and Find Full Text PDF

Introduction: The aim of this study was to examine the temperature changes on root canal and root surface in immature teeth with thin dentinal walls when irrigation solutions are preheated or intracanal heated, as well as the additional effects of passive ultrasonic irrigation (PUI) on these temperature changes.

Methods: Sixteen maxillary canine teeth were trimmed to a length of 20 mm and prepared to mimic immature teeth with an apical width of 1.3 mm by enlarging those using Gates Glidden burs.

View Article and Find Full Text PDF

Background: Antimicrobial endodontic intracanal medicaments play a vital role along with biomechanical preparation in the elimination of bacteria present in the pulp area to achieve success in endodontic therapy.

Aim: The present research was conducted with the objective of evaluating and comparing intracanal medicaments regarding antibacterial properties against .

Materials And Methods: One hundred and twenty healthy human premolars of the mandible were used.

View Article and Find Full Text PDF

XP-Endo Finisher behaviour and irrigant temperature in intracanal environment: Clinical measurements.

Int Endod J

January 2025

Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil.

Aim: To evaluate the behaviour of the XP-Endo Finisher and the variation in the intracanal temperature of the irrigant at rest and when activated over time.

Methodology: Differential scanning calorimetry (DSC) determined the transformation temperatures of XP-Endo Finisher instruments. A digital thermocouple was used to measure the temperature of the irrigant inside the pulp chamber.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to evaluate effect of cryotreated and warm sodium hypochlorite (NaOCl) on postoperative pain in patients with symptomatic irreversible pulpitis and symptomatic apical periodontitis.

Methods: Sixty-six individuals with preoperative pain scores of ≥54 mm on the Heft Parker Visual Analogue Pain Scale (HP-VAS) diagnosed with symptomatic irreversible pulpitis and symptomatic apical periodontitis as per the American Association of Endodontists guidelines in mandibular molars were included. The preparation of the access and the root canals was instrumented and irrigated in accordance with a standard protocol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!