A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Correlation between the radial artery resistance index and the systemic vascular resistance index: a cross-sectional study. | LitMetric

Introduction: Ultrasound measurement of the radial resistance index (RRI) in the anatomical snuffbox has been proposed as a useful method for assessing the systemic vascular resistance index (SVRI). This study aims to establish the correlation between SVRI measured by pulmonary artery catheter (PAC) and RRI.

Methods: A cross-sectional study included all consecutive patients undergoing postoperative (POP) cardiac surgery with hemodynamic monitoring using PAC. Hemodynamic assessment was performed using PAC, and RRI was measured with ultrasound in the anatomical snuffbox. The Pearson correlation test was used to establish the correlation between RRI and SVRI measured using PAC. Hemodynamic behavior concerning RRI with a cutoff point of 1.1 (described to estimate under SVRI) was examined. Additionally, consistency between two evaluators was assessed for RRI using the intraclass correlation coefficient and Bland-Altman analysis.

Results: A total of 35 measurements were obtained. The average cardiac index (CI) was 2.73 ± 0.64 L/min/m², and the average SVRI was 1967.47 ± 478.33 dyn·s·m²/cm. The correlation between RRI and SVRI measured using PAC was 0.37 [95% CI 0.045-0.62]. The average RRI was 0.94 ± 0.11. RRI measurements > 1.1 had a mean SVRI of 2120.79 ± 673.48 dyn·s·m²/cm, while RRI measurements ≤ 1.1 had a mean SVRI of 1953.1 ± 468.17 dyn·s·m²/cm (p = 0.62). The consistency between evaluators showed an intraclass correlation coefficient of 0.88 [95% CI 0.78-0.93], and Bland-Altman analysis illustrated adequate agreement of RRI evaluators.

Conclusions: For patients in cardiac surgery POP, the correlation between the SVRI measured using PAC and the RRI measured in the anatomical snuffbox is low. Using the RRI as a SVRI estimator for patients is not recommended in this clinical scenario.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130094PMC
http://dx.doi.org/10.1186/s13089-024-00379-0DOI Listing

Publication Analysis

Top Keywords

svri measured
16
rri
12
anatomical snuffbox
12
rri svri
12
measured pac
12
svri
10
correlation
8
systemic vascular
8
vascular resistance
8
cross-sectional study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!