AI Article Synopsis

Article Abstract

Background: Careful selection of patients for carotid stenting is necessary. We suggest that patients with a shaggy aorta syndrome may be at higher risk for perioperative embolic complications.

Methods: The study is a retrospective subanalysis of the SIBERIA Trial. We included 72 patients undergoing transfemoral carotid artery stenting. Patients were monitored during the procedures using multifrequency transcranial Doppler with embolus detection and differentiation. Pre- and postprocedural (2 and 30 days) cerebral diffusion-weighted cerebral MRIs were performed.

Results: Forty-six patients had shaggy aorta syndrome. Intraoperative embolisms were recorded in 82.6% and 46.1% of patients with and without shaggy aorta syndrome, respectively (P=0.001). New asymptomatic ischemic brain lesions in the postoperative period occurred in 78.3% and in 26.9% of patients with and without shaggy aorta syndrome, respectively (P<0.001). There were no cases of stroke within 2 days in both groups. 3 (6.5%) cases of stroke within 30 days after the procedure were observed only in patients with shaggy aorta syndrome. There were no cases of contralateral stroke. Shaggy aorta syndrome (OR 5.54 [1.83:16.7], P=0.001) and aortic arch ulceration (OR 6.67 [1.19: 37.3], P=0.02) were independently associated with cerebral embolism. Shaggy aorta syndrome (OR 9.77 [3.14-30.37], P<0.001) and aortic arch ulceration (OR 12.9 [2.3: 72.8], P=0.003) were independently associated with ipsilateral new asymptomatic ischemic brain lesions.

Conclusions: Shaggy aorta syndrome and aortic arch ulceration significantly increase the odds of intraoperative embolism and new asymptomatic ischemic brain lesions. Carotid endarterectomy or transcervical carotid stent should be selected in patients with shaggy aorta syndrome.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S0392-9590.24.05150-2DOI Listing

Publication Analysis

Top Keywords

shaggy aorta
20
patients shaggy
16
aorta syndrome
16
carotid artery
8
artery stenting
8
stenting patients
8
patients
7
aorta
5
impact shaggy
4
aorta intraoperative
4

Similar Publications

Moderate hypothermic circulatory arrest with antegrade cerebral perfusion for the open repair of juxtarenal abdominal aortic aneurysm repair with shaggy aorta.

J Vasc Surg Cases Innov Tech

February 2025

Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Case Western Reserve University School of Medicine, University Hospitals, Harrington Heart and Vascular Institute, Cleveland, OH.

Shaggy aorta is severe luminal surface degeneration of the aorta leading to an increased risk of plaque destabilization and embolization to the peripheral or visceral vessel beds. It represents a challenging clinical entity for both endovascular and open repair owing to potential atheroembolization, increased early morbidity and mortality, and poor long-term survival. Patients may be denied repair owing to its high risks.

View Article and Find Full Text PDF

Ascending aortic replacement is a basic procedure in aortic surgery. The crucial factor is the anastomosis method, including the anastomosis site formation. The anastomosis method is usually completely different between true aneurysms and acute aortic dissection because of the difference in the fragility of the aorta.

View Article and Find Full Text PDF

Shaggy aorta (SA) is characterized by a critical and extensive atheromatous disease of the thoracic and abdominal aorta. This degenerative and dangerous pathology is the result of the confluence of multiple modifiable and non-modifiable risk factors. The clinical importance of this pathology relies on the various syndromes that can develop from its etiopathogenesis, which generates great morbidity and mortality in the affected patients.

View Article and Find Full Text PDF

Objectives: To evaluate the blood flow velocity and wall shear stress in total arch replacement with a "shaggy" aorta, using computational fluid dynamics, and determine the optimal cannulation method.

Methods: A patient-specific aortic arch aneurysm model was constructed by using computed tomography scans. Three cannulas were assessed, as follows: dispersive with a steep angle, dispersive with a gentle angle, and the endo-hole type.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!