Background: Uncontrolled and diffuse bleeding is a dreaded event during open and laparoscopic surgery that may lead to postoperative complications, obstruction of the surgical field that reduces visualization, and prolonged operating times. Powder hemostats can be used to control bleeding and are easy to use, have a safe profile, and can achieve broad coverage area at a low cost.

Methods: A strategic literature search of peer-reviewed, English language studies was conducted to capture evidence on the clinical efficacy and safety of a Microporous Polysaccharide Hemosphere (MPH) based Hemostat (Arista™ Absorbable Hemostat (Arista™ AH)).

Results: Six preclinical studies were found which supported the use of MPH in various animal models of laparoscopic and open surgery, all of which demonstrated its safety and efficacy. Five single-arm and 11 comparative clinical studies similarly supported the efficacy and safety of MPH in various surgery types, including cardiac, renal, and dermatologic surgery.

Conclusion: Published evidence supports the safe and effective use of MPH across a variety of surgical settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11127658PMC
http://dx.doi.org/10.2147/MDER.S442944DOI Listing

Publication Analysis

Top Keywords

arista™ absorbable
8
efficacy safety
8
hemostat arista™
8
studies supported
8
review evidence
4
evidence supporting
4
supporting arista™
4
absorbable powder
4
powder hemostat
4
hemostat background
4

Similar Publications

Studies on the Virucidal Effects of UV-C of 233 nm and 275 nm Wavelengths.

Viruses

December 2024

Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany.

Among the physical decontamination methods, treatment with ultraviolet (UV) radiation is a suitable means of preventing viral infections. Mercury vapor lamps (254 nm) used for room decontamination are potentially damaging to human skin (radiation) and harmful to the environment (mercury). Therefore, other UV-C wavelengths (100-280 nm) may be effective for virus inactivation on skin without damaging it, e.

View Article and Find Full Text PDF

Optical density measurement has been used for decades to determine the microorganism concentration and more rarely for mammalian cells. Although this measurement can be carried out at any wavelength, studies report a limited number of measurement wavelengths, mainly around 600 nm, and no consensus seems to be emerging to propose an objective method for determining the optimum measurement wavelength for each microorganism. In this article, we propose a method for analyzing the absorbance spectra of ESKAPEE bacteria and determining the optimum measurement wavelength for each of them.

View Article and Find Full Text PDF

Integrated Modeling and Target Classification Based on mmWave SAR and CNN Approach.

Sensors (Basel)

December 2024

Wireless Sensing and Imaging Laboratory & 6G Research Laboratory, SRM University AP, Amaravati 522502, India.

This study presents a numerical modeling approach that utilizes millimeter-wave (mm-Wave) Frequency-Modulated Continuous-Wave (FMCW) radar to reconstruct and classify five weapon types: grenades, knives, guns, iron rods, and wrenches. A dataset of 1000 images of these weapons was collected from various online sources and subsequently used to generate 3605 samples in the MATLAB (R2022b) environment for creating reflectivity-added images. Background reflectivity was considered to range from 0 to 0.

View Article and Find Full Text PDF

Distributed feedback lasers, which feature rapid wavelength tunability, are not presently available in the yellow and orange spectral regions, impeding spectroscopic studies of short-lived species that absorb light in this range. To meet this need, a rapidly tunable laser system was constructed, characterized, and demonstrated for measurements of the NH radical at 597.4 nm.

View Article and Find Full Text PDF

Background: 5-Aminosalicylic acid (5-ASA), the first-line therapy for ulcerative colitis, is a poorly soluble zwitterionic drug. Unformulated 5-ASA is thought to be extensively absorbed in the small intestine.

Methods: The pH-dependent solubility of 5-ASA in vitro and the intestinal membrane distribution of 5-ASA and its N-acetyl metabolite (AC-5-ASA) after the oral administration of 5-ASA were examined in fed rats.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!