A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Distinguishing motion artifacts during optical fiber-based hemodynamics recordings from brain regions of freely moving rodents. | LitMetric

Significance: Motion artifacts in the signals recorded during optical fiber-based measurements can lead to misinterpretation of data. In this work, we address this problem during rodent experiments and develop a motion artifacts correction (MAC) algorithm for single-fiber system (SFS) hemodynamics measurements from the brains of rodents.

Aim: (i) To distinguish the effect of motion artifacts in the SFS signals. (ii) Develop a MAC algorithm by combining information from the experiments and simulations and validate it.

Approach: Monte-Carlo (MC) simulations were performed across 450 to 790 nm to identify wavelengths where the reflectance is least sensitive to blood absorption-based changes. This wavelength region is then used to develop a quantitative metric to measure motion artifacts, termed the dissimilarity metric (DM). We used MC simulations to mimic artifacts seen during experiments. Further, we developed a mathematical model describing light intensity at various optical interfaces. Finally, an MAC algorithm was formulated and validated using simulation and experimental data.

Results: We found that the 670 to 680 nm wavelength region is relatively less sensitive to blood absorption. The standard deviation of DM () can measure the relative magnitude of motion artifacts in the SFS signals. The artifacts cause rapid shifts in the reflectance data that can be modeled as transmission changes in the optical lightpath. The changes observed during the experiment were found to be in agreement to those obtained from MC simulations. The mathematical model developed to model transmission changes to represent motion artifacts was extended to an MAC algorithm. The MAC algorithm was validated using simulations and experimental data.

Conclusions: We distinguished motion artifacts from SFS signals during in vivo hemodynamic monitoring experiments. From simulation and experimental data, we showed that motion artifacts can be modeled as transmission changes. The developed MAC algorithm was shown to minimize artifactual variations in both simulation and experimental data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11123205PMC
http://dx.doi.org/10.1117/1.NPh.11.S1.S11511DOI Listing

Publication Analysis

Top Keywords

motion artifacts
36
mac algorithm
24
artifacts sfs
12
sfs signals
12
simulation experimental
12
transmission changes
12
artifacts
11
optical fiber-based
8
motion
8
sensitive blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!