Introduction: Bilateral microprocessor-controlled prosthetic knee (MPK) users have unique needs in traversing environmental barriers compared to unilateral users. An enhancement to the Genium™/Genium X3™ MPK which included an updated ruleset, hydraulics, and new bilateral parameter presets was made to improve safety while stumbling and the smoothness of gait for all users while also improving the experience of bilateral users. The purpose of the study was to evaluate the effectiveness of the enhancements in a sample with unilateral and bilateral amputation.

Methods: A convenience sample of MPK users was recruited from two sites in the USA in two phases. Assessments included the -Test of Functional Mobility, Activity-specific Balance Confidence Scale, Prosthetic Limb User Survey of Mobility, a study-specific questionnaire, and the Comparative Activities of Daily Living (ADL) Questionnaire. Statistical significance of extracted data was tested with the Wilcoxon Rank-Sum Test for independent data and Wilcoxon Signed-Rank for paired data with an significance level of < 0.05. Unilateral subjects were age-matched to the group of bilateral subjects for between-groups and within-groups analyses.

Results: Twenty-six subjects (= 26) were enrolled. Stumble frequency reduced 85% from 16.0 ± 39.7 to 2.4 ± 2.3 (= 0.008) between baseline and final assessment overall. The bilateral group reported 50% ( = 0.009) and 57% ( = 0.009) greater relative improvement in patient-reported ease and safety, respectively, of completing ADLs compared to the unilateral group. The unilateral group reported residual limb pain and low back pain reduced from 2.3 to 1.4 ( = 0.020) and 3.8 to 1.8 ( = 0.027), respectively, whereas the bilateral group did not.

Discussion: Substantial reductions in stumbles, residual limb pain, and back pain were shown overall. These reductions were driven by the unilateral group who also showed improvements in comfort, exertion, and concentration while walking. The enhancements to the knee likely reduced some gait asymmetry for unilateral users. Improvements in patient-reported ease and safety of completing ADLs were shown overall and were driven by the bilateral group. This study shows further improvement in patient experience is achievable through innovation in MPK technology even for patients who appear to be functioning well.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11122470PMC
http://dx.doi.org/10.3389/fresc.2024.1342370DOI Listing

Publication Analysis

Top Keywords

unilateral bilateral
8
bilateral users
8
mpk users
8
users
6
bilateral
5
enhancement genium™
4
genium™ microprocessor-controlled
4
microprocessor-controlled knee
4
knee improves
4
improves safety
4

Similar Publications

Introduction: Bilateral facial nerve palsy (FNP) is a rare condition that is idiopathic in only 20%. FNP is the most common cranial neuropathy in West Nile neuroinvasive disease (WNND) but is usually unilateral and only a few cases of bilateral FNP have been reported.

Case: We present a case of a 65-year-old woman with confirmed WNND and simultaneous bilateral FNP.

View Article and Find Full Text PDF

Purpose: To compare the postoperative outcomes of corticosteroid therapy following biopsy with those following debulking surgery in patients with immunoglobulin G4 (IgG4)-related ophthalmic disease (IgG4-ROD).

Study Design: Retrospective comparative study.

Methods: Fifteen patients diagnosed with IgG4-ROD (5 unilateral, 10 bilateral) were retrospectively analyzed.

View Article and Find Full Text PDF

Factors associated with the time of glaucoma-related adverse events onset after pediatric cataract surgery and the preferred anti-glaucomatous surgical selection.

Int Ophthalmol

January 2025

Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, 83 Fenyang Road, Shanghai, 200031, China.

Purpose: To describe the clinical characteristics of glaucoma-related adverse events (GRAE) after pediatric cataract surgery. More importantly, to identify the factors associated with the time of GRAE onset and the preferred anti-glaucomatous surgical procedure for this disease.

Methods: Hospitalized medical records of patients who developed GRAE, which include glaucoma and glaucoma suspect, after pediatric cataract surgery (surgical age ≤ 14 years) between 1994 and 2021 were retrospectively reviewed.

View Article and Find Full Text PDF

Introduction: Clubfoot is at times associated with other lower extremity abnormalities, such as leg length discrepancy (LLD). Initial studies in patients treated with extensive soft tissue release (STR) have estimated that LLD is prevalent in 9% to 11% of children with idiopathic clubfoot. However, Ponseti-style serial casting has since replaced STR as the preferred clubfoot treatment method.

View Article and Find Full Text PDF

Background: Spontaneous pneumothorax (SP) has been reported to be associated with osteosarcoma lung metastases, but the computed tomography (CT) characteristics of lung metastases in patients with pneumothorax have not been comprehensively described. The study aimed to describe the CT characteristics of lung metastases in patients with osteosarcoma and to identify factors associated with SP.

Methods: This study comprised 123 patients diagnosed with osteosarcoma lung metastasis at our hospital between January 2016 and December 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!