Immediate versus delayed sequential bilateral ICL implantation: A retrospective comparison of vault height and visual outcomes.

Asia Pac J Ophthalmol (Phila)

Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China; Key laboratory of Myopia and Related Eye Diseases, National Health Commision, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China; Key laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences. Electronic address:

Published: June 2024

AI Article Synopsis

Article Abstract

Purpose: To compare the visual outcomes and risks of suboptimal vault-related complications between immediate sequential bilateral ICL surgery (ISBICLS) and delayed sequential bilateral ICL surgery (DSBICLS).

Design: A retrospective cohort study.

Methods: Patients who underwent bilateral ICL implantation between November 2014 and December 2021 at the Eye and ENT Hospital of Fudan University (Shanghai, China) were included and divided into two groups: (1) ISBICLS: both eye surgeries performed on the same day, and (2) DSBICLS: second eye surgery performed < 7 days following the first one. Propensity score matching (PSM) was performed to compare the visual outcomes. Multivariable logistic regression models were used to estimate the odds ratios (ORs) of the suboptimal vaults.

Results: Finally, 10,985 eyes were included. After PSM, 204 first surgery eyes and 162 s surgery eyes with complete postoperative data were matched. The safety and efficacy indices did not statistically differ between groups (all > 1.00), except that ISBICLS first surgery eyes achieved better efficacy index than DSBICLS group (1.03 ± 0.26 vs. 1.08 ± 0.23, P = 0.034). Excessive vault was observed in eight (4.06 %) ISBICLS first eyes, one (0.50 %) DSBICLS first eye, and none in the second surgery eye in either group. An insufficient vault was observed in one second eye and one DSBICLS second eye. We found no evidence of differences in the rate of excessive vault (OR = 0.831, 95 % CI: 0.426-1.622, P = 0.588) or insufficient vault (OR = 0.609, 95 % CI:0.062-5.850, P = 0.668).

Conclusion: ISBICLS provided safety, efficacy, and refraction predictability comparable to DSBICLS without increasing the risk of suboptimal vault-related complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apjo.2024.100075DOI Listing

Publication Analysis

Top Keywords

bilateral icl
16
sequential bilateral
12
second eye
12
delayed sequential
8
icl implantation
8
visual outcomes
8
suboptimal vault-related
8
vault-related complications
8
icl surgery
8
dsbicls second
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!