Retention rate of vagus nerve stimulation for the treatment of drug-resistant epilepsy: A single-centre, retrospective study.

Epilepsy Res

Department of Neurology, University Hospitals Leuven, Herestraat 49, Leuven 3000, Belgium; Laboratory for Epilepsy Research, KU Leuven, Leuven, Belgium. Electronic address:

Published: July 2024

The aim of this single-centre, retrospective, observational study was to evaluate long-term effectiveness of vagus nerve stimulation (VNS) in drug-resistant epilepsy (DRE) by using retention rate as a surrogate measure for seizure reduction. We included all patients with DRE, treated at the adult neurology department of the University Hospitals Leuven and who started VNS therapy from January 1, 1994, until May 1, 2021, with follow-up data cutoff on January 1, 2023. Retention rate of VNS was defined as the percentage of patients who maintain VNS at established time points. We estimated cumulative retention rate and battery replacement rate and correlated these with seizure reduction, using Kaplan-Meier analysis. Statistical analysis of potential predictors of VNS outcome (age, sex and epilepsy duration at implantation) was performed using mono- and multivariate analyses. VNS was started in 110 patients with DRE, with a mean follow-up of 8.7 years (SD 6.5). VNS was discontinued in 55 patients (50%), with ineffectiveness as the main reason for discontinuation (98%). The battery was replaced at least once in 42 patients (38%). Estimated retention rates were 70%, 52%, 45% and 33% after 5, 10, 15 and 20 years, respectively. Estimated first battery replacement rates were 16%, 42% and 47% after 5, 10 and 15 years, respectively. Both estimates showed a statistically significant correlation with seizure reduction. No independent predictors of long-term outcome of VNS were found. This is the first long-term study using retention rate of VNS to assess effectiveness. VNS is a well-tolerated therapy, but retention rates decline with long follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.eplepsyres.2024.107383DOI Listing

Publication Analysis

Top Keywords

retention rate
20
seizure reduction
12
vns
9
vagus nerve
8
nerve stimulation
8
drug-resistant epilepsy
8
single-centre retrospective
8
patients dre
8
rate vns
8
battery replacement
8

Similar Publications

Achieving high ionic conductivity and stable performance at low temperatures remains a significant challenge in sodium-metal batteries (SMBs). In this study, we propose a novel electrolyte design strategy that elucidates the solvation structure-function relationship within mixed solvent systems. A mixture of diglyme and 1,3-dioxolane was developed to optimize the solvation structure towards superior low-temperature electrolyte.

View Article and Find Full Text PDF

RP-HPLC technique was developed and optimized for simultaneous identification and estimation of nirmatrelvir (NIR) and ritonavir (RIT) in their new copackaged tablet. Stability of nirmatrelvir (NIR) was studied after exposure to different five stress conditions; alkali, acid, heat, photo and oxidation degradation. The chromatographic separation was achieved using VDSpher PUR 100 ODS (4.

View Article and Find Full Text PDF

Nickel-rich cobalt-free layered oxide cathode with Ni contents no fewer than 90 % has received extensive attention in the field of lithium-ion batteries due to its excellent specific capacity and low cost, but serious capacity degeneration induced by structural deterioration and interfacial instability greatly hamper their further development. Herein, the Sb-modified LiNiMnO materials from the interface to interior have been designed and fabricated to overcome the above issues. On the one hand, the introduction of Sb-ion in interior of grains can generate Sb-O chemical bond with high dissociation energy, which contributes to reinforce the chemical and structural stability.

View Article and Find Full Text PDF

Objective: To examine retention and compliance to a novel physical therapy (PT) treatment among Veterans with and without executive function deficits (EFD+/EFD-).

Design: This study was a preplanned secondary analysis of an ongoing randomized controlled trial.

Setting: Outpatient PT at VA Boston Healthcare System.

View Article and Find Full Text PDF

Silicon is widely recognized as a promising anode material for all-solid-state batteries (ASSBs) due to exceptional specific capacity, abundant availability, and environmental sustainability. However, the considerable volume expansion and particle fragmentation of Si during cycling lead to significant performance degradation, limiting its practical application. Herein, the development of a pre-lithiated Si-based composite anode (c-LiSi) is presented, designed to address the key challenges faced by Si-based anodes, namely severe volume changes and low electrochemical stability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!