This article proposes a new self-calibration method for circular encoders based on inertia and a single read-head. The velocity curves of the circular encoder are fitted with polynomials and, based on the principle of circle closure and the periodicity of the distribution for angle intervals, the proportionality between the theoretical value and the actual value of each angle interval is obtained. In the experimental system constructed, the feasibility of the proposed method was verified through self-calibration experiments, repeatability experiments, and comparative experiments with the time-measurement dynamic reversal (TDR) method. In addition, this article also proposes an iterative method to improve the self-calibration accuracy. Experimental verification was carried out, and the results show that the new method can effectively compensate for the error of angle measurement in the circular encoder. The peak-to-peak value of the error of angle measurement was reduced from 239.343" to 11.867", and the repeatability of the calibration results of the new method was less than 2.77".

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11125150PMC
http://dx.doi.org/10.3390/s24103069DOI Listing

Publication Analysis

Top Keywords

self-calibration method
8
method circular
8
circular encoders
8
encoders based
8
based inertia
8
inertia single
8
single read-head
8
article proposes
8
circular encoder
8
error angle
8

Similar Publications

Identification and correction of phase delay errors for hemispherical resonator gyroscopes.

Sci Rep

January 2025

Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin, 150080, Heilongjiang, China.

The phase-delay error of the circuit system is the primary source of the output error observed in the hemispherical resonator gyroscope (HRG). Additionally, the temperature-dependent nature of the phase-delay error results in a deterioration of the initial calibration parameters, which, in turn, significantly impairs the performance of the gyroscope in its intended application. This paper proposes a self-calibration method to effectively suppress the impact of phase-delay error on the application performance of gyroscopes.

View Article and Find Full Text PDF

A High-Precision Temperature Compensation Method for TMR Weak Current Sensors Based on FPGA.

Micromachines (Basel)

November 2024

State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.

Tunnel magnetoresistance (TMR) sensors, known for their high sensitivity, efficiency, and compact size, are ideal for detecting weak currents, particularly leakage currents in smart grids. However, temperature variations can negatively impact their accuracy. This work investigates the effects of temperature variations on measurement accuracy.

View Article and Find Full Text PDF

The development of a sensory signal amplification approach is very crucial for rapid and precise detection of aflatoxin B (AFB). However, such approaches remain scarce due to the weak interactions between AFB and the sensing probes. Herein, the first example of a dual-excitation fluorescent platform for antibody-free AFB detection is reported, which is assembled by an ordered π-π stack of cationic perylene derivative (PTHA) and tris(2,2'-bipyridine)ruthenium(II) [Ru(bpy)].

View Article and Find Full Text PDF

Herein, the miniaturized thermal purge-and-trap (MTPT) device combined with self-calibration colorimetric/surface-enhanced Raman spectroscopy (SERS) dual-model optical sensors were designed for effective analysis of sulfur dioxide (SO) in wine. The SO can be rapidly separated from wine and enriched by MTPT device, ensuring colorimetric/SERS dual-model optical sensing based on Karl Fischer reaction. The high separation efficiency of miniaturized MTPT device combined with self-calibration of dual-model optical sensors significantly alleviate matrix interference and improve the detection accuracy.

View Article and Find Full Text PDF

Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!