Supraglottic airway devices such as laryngeal masks and i-gels are useful for airway management. The i-gel is a relatively new device that replaces the air-inflated cuff of the laryngeal mask with a gel-filled cuff. It remains unclear which device is more effective for neonatal resuscitation. We aimed to evaluate the dependence of successful airway management in neonatal simulators on the device type and providers' backgrounds. Ninety-one healthcare providers performed four attempts at airway management using a laryngeal mask and i-gel in two types of neonatal manikins. The dependence of successful insertions within 16.7 s (75th percentile of all successful insertions) on the device type and providers' specialty, years of healthcare service, and completion of the neonatal resuscitation training course was assessed. Successful insertion ( = 0.001) and insertion time ( = 0.003) were associated with using the i-gel vs. laryngeal mask. The providers' backgrounds were not associated with the outcome. Using the i-gel was associated with more successful airway management than laryngeal masks using neonatal manikins. Considering the limited effect of the provider's specialty and experience, using the i-gel as the first-choice device in neonatal resuscitation may be advantageous. Prospective studies are warranted to compare these devices in the clinical setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11119467PMC
http://dx.doi.org/10.3390/children11050530DOI Listing

Publication Analysis

Top Keywords

airway management
20
dependence successful
12
successful airway
12
providers' backgrounds
12
laryngeal mask
12
neonatal resuscitation
12
management neonatal
8
supraglottic airway
8
laryngeal masks
8
device type
8

Similar Publications

Background: Prolonged dependence on mechanical ventilation is a common occurrence in clinical ICU patients and presents significant challenges for patient care and resource allocation. Predicting prolonged dependence on mechanical ventilation is crucial for improving patient outcomes, preventing ventilator-associated complications, and guiding targeted clinical interventions. However, specific tools for predicting prolonged mechanical ventilation among ICU patients, particularly those with critical orthopaedic trauma, are currently lacking.

View Article and Find Full Text PDF

Comparative efficacy and safety of pulmonary surfactant delivery strategies in neonatal RDS: a network meta-analysis.

BMC Pulm Med

December 2024

Department of Neonatology, Children's Hospital of Chongqing Medical University, Chongqing, 400,014, China.

Purpose: To compare five pulmonary surfactant (PS) administration strategies for neonates with respiratory distress syndrome (RDS), including intubation-surfactant-extubation (InSurE), thin catheter administration, laryngeal mask airway (LMA), surfactant nebulization (SN), and usual care, with a particular emphasis on the comparison of the LMA and SN with other strategies.

Methods: We conducted a systematic search of MEDLINE, EMBASE, PUBMED, and Cochrane CENTRAL databases up to November 2023. Two authors independently conducted data extraction, and assessed bias using the Cochrane Risk of Bias Tool.

View Article and Find Full Text PDF

Background: We previously published the protocol and statistical analysis plan for a randomized controlled trial of Proportional Assist Ventilation for Minimizing the Duration of Mechanical Ventilation: the PROMIZING study in Trials ( https://doi.org/10.1186/s13063-023-07163-w ).

View Article and Find Full Text PDF

Background: Considerable morbidity is attributable to inappropriate tracheal cuff pressure. An earlier study undertaken in our hospital revealed that a normal cuff pressure of 20-30 cm HO was achieved in only 6% of intubated patients using subjective estimation methods.

Objective: To determine whether a training intervention could improve the accuracy of the subjective estimation method in our tracheal cuff monitoring.

View Article and Find Full Text PDF

Arteriovenous malformations (AVMs) in the head and neck present significant challenges due to airway management complexities and hemorrhage risks. This case report describes a 15-year-old female with a congenital facial AVM causing dyspnea and obstructive symptoms. The patient required angioembolization of the AVM, but many hospitals deferred the procedure due to the anticipated difficult airway and severe bleeding risks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!