Purpose: To report the clinical results obtained with fixed short-span (single crowns [SCs] and fixed partial prostheses [FPPs]) implant-supported hybrid composite restorations fabricated through tilting stereolithography (TSLA).

Methods: This retrospective clinical study included 85 patients who had been restored with 95 fixed short-span implant-supported hybrid composite (Irix Max®, DWS Systems) restorations (70 SCs and 25 FPPs up to three units) fabricated with TSLA. The full-digital model-free workflow was based on intraoral implant scanning, computer-assisted design (CAD) and 3D printing using TSLA (Dfab®, DWS Systems). The primary outcomes were the marginal adaptation, the quality of the occlusal and interproximal contact points, and the chromatic integration of the restorations, assessed independently by two experienced operators (a prosthodontist and a periodontist). A score from 1 to 5 (with 5 as the highest value, 4 for satisfactory quality, 3 for acceptable quality, and 2 and 1 as the lowest values, expressing unsatisfactory quality) was assigned by each operator to each restoration at delivery. The secondary outcomes were the survival and success of the restorations at the 1-year follow-up. The restoration was defined as successful in the absence of any complications throughout the follow-up period. A statistical analysis was conducted.

Results: For the quality of the marginal closure and occlusal and interproximal contact points, the 3D-printed hybrid composite restorations scored highly; the aesthetic integration was satisfactory. One year after placement, all restorations survived, with a low incidence (4.2 % overall, 5.7 % SCs) of complications (two abutment screw loosenings, two decementation of the restorations, and one upper portion of the hybrid abutment decemented from the titanium base), for a success rate of 95.8 %.

Conclusions: Within the limits of this study (retrospective design, follow-up limited to 1 year from the delivery, and only cemented restorations included) fixed short-span implant-supported hybrid composite crowns and bridges fabricated through TSLA were clinically precise, presenting a low incidence of complications at 1 year.

Statement Of Clinical Relevance: The use of TSLA printing technology can open new perspectives for the treatment of small edentulous gaps with definitive implant-supported prosthetic restorations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2024.105095DOI Listing

Publication Analysis

Top Keywords

hybrid composite
20
fixed short-span
12
implant-supported hybrid
12
restorations
10
restorations fabricated
8
fabricated tilting
8
tilting stereolithography
8
retrospective clinical
8
clinical study
8
composite restorations
8

Similar Publications

An aerobic, Gram-stain-positive, motile, coccus-shaped actinomycete, designated strain LSe6-4, was isolated from leaves of sea purslane (Sesuvium portulacastrum L.) in Thailand and subjected to a polyphasic taxonomic studies. Growth of the strain occurred at temperatures between 15 and 38 °C, and with NaCl concentrations 0-13%.

View Article and Find Full Text PDF

Microprofiling real time nitric oxide flux for field studies using a stratified nanohybrid carbon-metal electrode.

Anal Methods

November 2017

Agricultural and Biological Engineering Department, Institute of Food and Agricultural Sciences, University of Florida, Gainesville, FL, USA.

Nitric oxide (NO) is an important signaling molecule that is involved in stress response, homeostasis, host defense, and cell development. In most cells, NO levels are in the femtomolar to micromolar range, with extracellular concentrations being much lower. Thus, real time measurement of spatiotemporal NO dynamics near the surface of living cells/tissues is a major challenge.

View Article and Find Full Text PDF

The comprehensive benefit evaluation of LID based on multi-criteria decision-making methods faces technical issues such as the uncertainties and vagueness in hybrid information sources, which can affect the overall evaluation results and ranking of alternatives. This study introduces a multi-indicator fuzzy comprehensive benefit evaluation approach for the selection of LID measures, aiming to provide a robust and holistic framework for evaluating their benefits at the community level. The proposed methodology integrates quantitative environmental and economic indicators with qualitative social benefit indicators, combining the use of the Storm Water Management Model (SWMM) and ArcGIS for scenario-based analysis, and the use of hesitant fuzzy language sets and Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) for decision-making.

View Article and Find Full Text PDF

Hydrogel coils in intracranial aneurysm treatment: a multicenter, prospective, randomized open-label trial.

J Neurosurg

January 2025

19Division of Medical Statistics, Division of Data Science, Foundation for Biomedical Research and Innovation at Kobe; and.

Objective: Studies have demonstrated the effectiveness of hydrogel-coated coils (HGCs) to achieve the composite endpoint of decreased recanalization rates and greater safety. Herein, the authors aimed to assess the true ability of second-generation HGCs to prevent recanalization.

Methods: This randomized controlled study, the HYBRID (Hydrocoil Versus Bare Platinum Coil in Recanalization Imaging Data) trial, comparing HGCs with bare platinum coils (BPCs), was conducted in 43 Japanese institutions.

View Article and Find Full Text PDF

Skin cancer is considered globally as the most fatal disease. Most likely all the patients who received wrong diagnosis and low-quality treatment die early. Though if it is detected in the early stages the patient has fairly good chance and the aforementioned diseases can be cured.

View Article and Find Full Text PDF