A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of biomechanical performance of titanium and polyaryletheretherketone miniscrews at different insertion angles: A finite element analysis. | LitMetric

AI Article Synopsis

  • Miniscrews, made from titanium (Ti), provide absolute anchorage in orthodontics but have several disadvantages, while polyaryletheretherketone (PEEK) may offer potential advantages as an alternative material.
  • This study utilizes finite element analysis (FEA) to compare the biomechanical performance of Ti and PEEK miniscrews under various insertion angles and loads.
  • Results indicate that while PEEK generates more stress in the bone compared to Ti, it presents a viable option for TAD fabrication based on its biomechanical performance insights.

Article Abstract

Introduction: Only miniscrews [temporary anchoring devices, (TADs)] can provide absolute anchorage during orthodontic treatment. Titanium (Ti) is a fundamental material used in the production of miniscrews, but it has many disadvantages. Polyaryletheretherketone (PEEK) may have various benefits in the production of miniscrews. Finite element analysis (FEA) is a valid and reliable method for calculating stress, strain, and loading forces on complex structures and can be more time- and cost-efficient.

Objective: To investigate the biomechanical performance of Ti and PEEK as miniscrew biomaterials employing FEA.

Materials And Methods: This study is a 3-D (3D) simulation with FEA. First, 3D miniscrew modeling is done using Ti base material and PEEK (1.4 mm × 6 mm size), as well as 3D inter-radicular space bone modeling. The simulation was performed by modeling the insertion angles (30°, 60°, and 90°) and applying a 200-gram loading force. The biomechanical performance of the miniscrew was then determined using FEA.

Results: As the angle of insertion increases, the tension on the bone decreases, the stress on the TADs increases, and the bone deformation decreases. Compared to TADs made of Ti and PEEK, TADs made of PEEK alone cause more bone stress than TADs made of Ti. The distortion in the maxilla is observed to be larger than in the mandibular.

Conclusion: PEEK has greater stress on the bones than Ti and may be prospected as an alternative biomaterial for TAD fabrication, as documented in the FEA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11114449PMC
http://dx.doi.org/10.4103/jos.jos_102_23DOI Listing

Publication Analysis

Top Keywords

biomechanical performance
12
insertion angles
8
finite element
8
element analysis
8
production miniscrews
8
stress tads
8
tads peek
8
peek
6
comparison biomechanical
4
performance titanium
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!